The number stamped on orifices correspond
to each respective size log set as indicated by
model numbers as shown in table below.
Model #
SSEAV18RP
SSEAV24RP
SSWV24RP
SSWV30RP
For an 18 in. or 30 in. log set, use a 10 mm
socket or nut driver to remove the orifice from the
propane/LP burner air mixer (A).
3. Using pipe sealant on the thread of the larger
end of fitting, screw the propane/LP burner air
mixer (A) through hole and into burner manifold
as shown in Fig. 3. Tighten using a wrench.
Follow steps 1 through 7 under Natural
Gas Installation, page 4.
OPERATING INSTRUCTIONS
Changing Pilot Orifice
The pilot is provided with a natural gas injector
installed. For Propane/LP gas you must remove
it and replace it with the Propane/LP injector (J)
("LP" printed on the surface).
1. Gently loosen and remove the pilot gas pipe
from bracket. Replace the injector with the
Propane/LP pilot injector (J) with "LP" printed on
injector surface. Place and tighten the pilot gas
pipe to bracket as shown on Fig 1.
Continue with step 3 under Natural Gas
Installation, page 4.
Orifice
Orifice #
G
18
H
24
H
24
I
30
7
Fig.3
Fig. 1
J
A
Need help?
Do you have a question about the NVDWA1 and is the answer not in the manual?