Procom NVDWA1 Instructions Manual page 7

Manual on/off valve safety pilot kit
Table of Contents

Advertisement

The number stamped on orifices correspond
to each respective size log set as indicated by
model numbers as shown in table below.
Model #
SSEAV18RP
SSEAV24RP
SSWV24RP
SSWV30RP
For an 18 in. or 30 in. log set, use a 10 mm
socket or nut driver to remove the orifice from the
propane/LP burner air mixer (A).
3. Using pipe sealant on the thread of the larger
end of fitting, screw the propane/LP burner air
mixer (A) through hole and into burner manifold
as shown in Fig. 3. Tighten using a wrench.
Follow steps 1 through 7 under Natural
Gas Installation, page 4.
OPERATING INSTRUCTIONS
Changing Pilot Orifice
The pilot is provided with a natural gas injector
installed. For Propane/LP gas you must remove
it and replace it with the Propane/LP injector (J)
("LP" printed on the surface).
1. Gently loosen and remove the pilot gas pipe
from bracket. Replace the injector with the
Propane/LP pilot injector (J) with "LP" printed on
injector surface. Place and tighten the pilot gas
pipe to bracket as shown on Fig 1.
Continue with step 3 under Natural Gas
Installation, page 4.
Orifice
Orifice #
G
18
H
24
H
24
I
30
7
Fig.3
Fig. 1
J
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NVDWA1 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

0011258

Table of Contents