Download Print this page

Specifications - ADC HiGain HLU-C-388 List 5F Quick Installation

Line unit

Advertisement

HLU-388 L
®
The HiGain
repeaterless T1 transmission system. When used in conjunction with a HiGain Remote
Unit (HRU), the system provides 1.544 Mbps transmission on two unconditioned
copper pairs over the full Carrier Service Area (CSA) range. The CSA includes loops
up to 12,000 feet of 24 American Wire Gauge (AWG) or 9,000 feet of 26 AWG wire,
including bridged taps. This line unit can be used in applications with or without
HiGain Doubler Units (HDUs).
F
EATURES
• Front panel status LED, craft port, and
four-character status display
• Ultra-low wander
• Five-span range with four doublers
(60 kft, 24 AWG)
• Selectable Power Feed modes
• Loss of Signal (LOS)/Alarm Indicator
Signal (AIS) payload alarm option
• Supports Pulsecom HDSL 62/64 applications
• B8ZS default line code option
• Bipolar Violation Transparency (BPVT) option
S
PECIFICATIONS
Operating Temperature
Operating Humidity
HDSL Span Voltage
Mounting
HDSL Line Code
HDSL Output
Maximum Provisioning Loss
DS1 Line Rate
DS1 Line Format
DS1 Frame Format
DSX-1 Pulse Output
DSX-1 Input Level
5F
IST
Line Unit HLU-388 List 5F is the Central Office (CO) side of a
• Payload (PL) or HiGain (HG) loopback source
identification
• Reduced power consumption
• Low line-power option (-140 V) for circuits
with a single doubler
• Bit Error Rate (BER) alarm options
• Additional screens for inventory and
troubleshooting
• Grounded loop detection
• Unframed (UNFR) default framing option
-40 °F to 149 °F (-40 °C to + 65°C)
5% to 95% non-condensing
-140 ±112 Vdc
DDM+ high-density shelf
784 kbps 2B1Q
+13.5 dBm ±0.5 dB, 135 Ω
35 dB at 196 kHz, 135 Ω
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI) or Bipolar with
8-Zero Substitution (B8ZS)
Extended SuperFrame (ESF), SuperFrame (SF),
or Unframed (UNFR)
pk-pk
6 V
, pre-equalized for 0 to 655 feet of ABAM
cable
+1.5 to -7.5 dB DSX

Advertisement

loading