Download Print this page

Lincoln Electric FLEXTEC350x CE CONSTRUCTION Operator's Manual page 10

Advertisement

Case Back Controls
1.
Control Circuit Breaker
20 amps on all models
2.
Auxiliary Power Circuit Breaker
10 amps on Standard model
3 amps on Construction model
3.
CE Filter
Internal Controls
The User Interface pc board has one bank of dip
switches. As shipped from the factory and under normal
conditions, the dip switches are all in the 'off' position.
There are 3 instances that require a change of the dip
switch.
English
Factory Default Setting
All Switches in the 'OFF' Position
Test Mode Setting
1.
Enter a test mode. This is utilized when the
machine is connected to a grid load for serving
a)
Turn switch #4 to the "ON" position.
Switch #4 in the 'ON' Position
VRD Enabled Setting
2.
Enter VRD mode (VRD Enabled)
a)
Turn switch #5 to the "ON" position.
Switch #5 in the 'ON' Position
Calibration
3.
Enter Calibration mode. This allows the machine
voltage and current to be calibrated while connected
to a grid load.
a)
Turn switch #1 to the "ON" position.
Switch #1 in the 'ON' Position
Wire Feeder & Digital Accessory
Connectivity
7
English

Advertisement

loading

This manual is also suitable for:

Flextec350x ce standardK4283-1K4284-1