BFT A-CT BOARD SW Installation Manual page 10

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
Lit:
START
- START input activated
- Radio receiver 1st channel activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
Unlit: PHOT photocell input activated
PHOT
Flashing: no photocell connected.
Unlit: motor 1 limit switches are disengaged
SW1
Lit: one of motor 1 limit switches is Engaged (leaf 1 is either fully
closed or fully open)
Unlit: motor 2 limit switches are disengaged
SW2
Lit: one of motor 2 limit switches is Engaged (leaf 2 is either fully
closed or fully open)
Unlit: no error
ER
Lit: error in safety device test or anti-crush safety device tripped
Flashing: Thermal overload protection tripped
Unlit: motors Stopped (Off )
MOTOR
Lit: motors Moving (On)
TABLE "A" - PARAMETERS
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGICS
DIP
Logic
Photocells
1
during opening
Block pulses
2
during opening
3
3-step logic
Transmitter
4
programming
5
1 Motor active
Reversing
6
motion
10 - A-CT BOARD SW
INSTALLATION MANUAL
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
0
99
WARNING: It affects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
Cross out
Default
setting used
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
RADIO
hidden key.
(GREEN)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset or search for mechanical stop in progress
SET
Fast flashing: Autoset failed
Flashing in sync with Radio LED: Transmitter deletion in progress
10) CONNECTION DIAGRAM FOR SEVERAL PAIRS (MAX. 4) OF A-CELLULA FLX
PHOTOCELLS FIG.G)
11) ADJUSTMENT PROCEDURE
- Before turning the unit on, check electrical connections.
- Set the following parameters: Automatic Closing Time, motor force.
- Set the logics.
- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors
idle (i.e. not overheated by a considerable number of consecutive operations).
Description
Description
In the event beam is broken, photocell operation is disabled during opening. During closing,
movement is reversed immediately.
When beam is broken, photocells are active during both opening and clo-
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
The start pulse has no effect during opening.
The start pulse has effect during opening.
Switches to 3-step logic; during closing, start
reverses movement.
Switches to 4-step logic.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new tran-
smitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
Only motor 2 active (1 leaf ).
Both motors active (2 leaves).
Reverses the motion of motors with respect to standard operating mode: the rod comes out
during opening; the rod returns during closing.
Standard operating mode: the rod returns during opening; the rod comes out during closing.
3 step
CLOSED
opens
DURINg CLOSINg
OPEN
closes
stop +
DURINg OPENINg
TCA
AFTER STOP
opens
4 step
opens
stop
closes
stop +
TCA
opens

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents