Location - Quincy QR-25 Series Instruction Manual

Hide thumbs Also See for QR-25 Series:
Table of Contents

Advertisement

Location

CAUTION !
WARNING !
QR-25 Series
52201-107, January 2014
ment at the premises where the delivery was made. Do not move the damaged
freight from the premises where the original delivery was made. Retain all
containers and packing for inspection by the carrier.
A claim form can be requested from the carrier: Standard Form for Pre-
sentation of Loss and Damage Claims (form # 3208). Your claim will need to
be substantiated with the following documents:
a.)
form #3208
b.)
original bill of lading
c.)
original paid freight bill
d.)
original invoice or certified copy
e.)
other particulars obtainable in proof of loss or damage (photos, dam-
age inspection, etc.)
The proper description and classification of our product in the National
Motor Freight Classification 100­H, contained in item 118100, reads as fol-
lows: Compressors, air, or air ends: with or without air tanks, hose or nozzles,
mounted or not mounted."
We suggest that these instructions be circulated to your shipping and
receiving personnel.
Quincy air compressors must be installed and operated in a secure, upright
position in an area that is clean, dry, well lighted, adequately ventilated and
not closer than 24 inches to a wall or another compressor. (Note: A gas engine
will produce carbon monoxide; always provide adequate ventilation!) Inspec-
tion and mainte nance checks are required daily. Therefore, sufficient space
needs to be provided around the compressor for safe and proper in spection,
cleaning, and maintenance.
Ample circu la tion of air must be provided across the compressor cylinders,
heads and cooler (if so equipped). Do not allow hot air from additional equip-
ment to blow towards the compressor unit. If at all possible, the pulley drive
system (i.e. motor pulley, compressor sheave, belts and guard) should be located
next to a wall to minimize any danger created by the drive system while the
compressor is operating.
QR­25 series compressors should be operated in temperatures under 104°F.
In cold cli mates, compressors should be installed in a heated building.
Do not operate this compressor in ambient temperatures lower
than -15° F. A crankcase heater is recommended for a compressor
that is to operate in temperatures under 32° F.
Under no circumstances should a compressor be used in an area
that may be exposed to toxic, volatile, or corrosive atmo sphere. Do
not store toxic, volatile, or corrosive agents near the compressor.
Noise
Noise is a potential health hazard that must be considered. There are federal
9
Quincy Compressor
3501 Wismann Lane, Quincy IL - 62305-3116

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents