Installation, Operation & Maintenance Instructions
GENERAL
This heat er is designed t o provide years of ef
f ort heat ing in resident ial and commercial applicat ions. Baseboard heat ers must be t hermost at ically cont rolled f or ef
operat ion. A t hermost at is not provided wit h t his heat er. However, a single or double pole t hermost at accessory is available f or
inst allat ion int o t his heat er at your place of purchase, or t he heat er may be connect ed t o any suit able wall mount ed t hermost at
t hat will meet t he elect rical load requirement s. Inst allat ion or use of t his product in any manner not described herein will void
t he warrant y and could result in inj ury, damage t o propert y, or permanent damage t o heat er.
WHEN USING ELECTRICAL APPLIANCES, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE FOLLOWING:
1)
Read all inst ruct ions bef ore inst alling or using t he heat -
er.
2)
A heat er has hot and arcing or sparking part s inside, Do
not use in areas where gasoline or
used or st ored.
3)
This heat er is hot when in use. To avoid burns, do not
let bare skin t ouch hot surf aces. Keep combust ible
mat erials, such as f urnit ure, pillows, bedding, papers,
clot hes, and curt ains away f rom heat er.
NAMEPLATE
King Electrical Mfg. Co.
Seattle, WA
Model 2B2405
VOLTS 208/220/240
WATTS 375/420/500
CAUTION: ALL WIREWAY WIRING MUST BE
APPROVED FOR 75 C WIRE AND DERATED 58%
NO MORE THAN 3 #10 AWG CONDUCTORS IN
WIREWAY WITH NO MORE THAN 2
ENERGIZED. FIELD WIRING COMPARTMENT
APPROVED FOR 60 DEGREE C WIRE. THE
INSTALL BOTTOM OF HEATER NO LESS THAN
3/4" ABOVE THE FINISHED FLOOR.
Figure 1: Nameplat e
electrical mfg company
IMPORTANT INSTRUCTIONS
fi
cient , t rouble f ree operat ion as a primary or supplement ary heat source f or com-
WARNING
fl
ammable liquids are
K SERIES 4
E
Locat ion
SAVE THESE INSTRUCTIONS
4)
To prevent a possible
fi
re, do not block air int akes or ex-
haust in any manner.
5)
Do not insert or allow f oreign obj ect s t o ent er any ven-
t ilat ion or exhaust opening as t his may cause an elect ric
fi
shock or
re, or damage t he heat er.
6)
Serious inj ury or deat h could result f rom elect ric shock.
Make sure elect rical power supply circuit coming t o heat -
er is disconnect ed at main disconnect or service panel
bef ore inst alling or servicing t his heat er.
Table 1
Tot al Amps
Minimum AWG.
Wire Size
(Copper)
0 t hru 12
#14
12. 1 t hru 16
#12
16. 1 t hru 24
#10
Table 2: Net Volumes of Wiring Compartment
Descript ion
Heat er Only
(Each Wiring Compart ment )
Heat er wit h SP Thermost at
Heat er wit h DP Thermost at
fi
cient , saf e
Circuit Breaker or
Fuse Size
15 amp
20 amp
30 amp
Cubic Inches
Cubic CM
49. 69
8. 14
44. 24
7. 25
44. 24
7. 25