KCV SERIES
Heater
It is extremely important to verify the electrical power supply is the same voltage as the heater being installed.
240 and 120 Volt heaters are not interchangeable. Powering a 240 Volt unit with 120 Volt supply wires will
reduce heater output by approximately 75%. Powering a 120 Volt unit with 240 Volt supply wires will destroy the
heater and voids all guarantee and warranties.
CAUTION: Turn off power source supplying heater before attempting
any installation, maintenance or repairs. Lock or tag circuit breaker/fuse
panel door. Failure to do so could result in serious electrical shock, burns
or possible death.
WARNINGS: To insure proper operation of this heater it should be a minimum
of 6 feet above the floor and no closer than 2½" below drywall ceiling
(6" vinyl or drop ceilings). Draperies should clear the front and the top of this
heater by 6". Draperies hung below the heater should have a 2½" clearance.
Do not block the heater in any manner. Never paint the heater.
Following the guidlines herein listed will result in a maintenance-free heater. There are no moving parts or motors
to maintain. Periodic dusting of the front panel is all that is suggested.
The KCV Cove Heater carries a (2) warranty form date of installation. Please refer to the manufacturer's warranty
statement for further information.
Cove heaters are completely assembled and pre-wired. To prepare
the heater for installation, carefully check the voltage to be used is
the same as stated on the rating nameplate. Operating voltage can
not exceed 5% of nameplate voltage. Operating heater above listed
voltage ratings voids all gaurantees and warranties.
KING ELECTRICAL MFG. COMPANY • 9131 10TH AVENUE SOUTH • SEATTLE, WA 98108 • PH: 206.762.0400 • FAX: 206.763.7738 • www.king-electric.com
Cove
MAINTENANCE & WARRANTY
GENERAL INFORMATION
SAVE THESE INSTRUCTIONS
Diag. A

Advertisement

loading

Summary of Contents for KING KCV Series

  • Page 1 5% of nameplate voltage. Operating heater above listed voltage ratings voids all gaurantees and warranties. SAVE THESE INSTRUCTIONS KING ELECTRICAL MFG. COMPANY • 9131 10TH AVENUE SOUTH • SEATTLE, WA 98108 • PH: 206.762.0400 • FAX: 206.763.7738 • www.king-electric.com...
  • Page 2 #$-%".."%#/$(#$-%+0'%#/$- Following are some general guidelines: • Do not recess this cove heater. • Voltage rating of heater should be the same as supply load. Disconnect power at main panel. • Make certain all wiring is in accordance with all •...
  • Page 3 Fig. D Fig. E After wiring is complete, carefully press the electrical wires into the junction box, making sure not to pinch any wires between the junction box and the heating panel. Install the end caps: Push the bottom edge of the aluminum heating panel towards the back panel, while installing the end caps and lightly tighten the 2 screws to secure it.