MPPT M4860ADS User Manual

Solar charge controller

Advertisement

Quick Links

Description of Functions
1. Suitable for charging 12V/24V/36V/48V lead-acid batteries, including GEL, Sealed, Flooded battery
2. Mainly suitable for off-grid solar power generation systems, such as: home solar power generation system, solar RV power generation,
boat, unattended base stations, outposts and so on.
3. MPPT charging technology, three-stage charging mode, constant current charge-constant voltage charge-floating charge,
effectively improve the battery charging efficiency. It is more portable than ordinary PWM charging.
4. Suitable for high voltage input, PV voltage up to 150 V (At the lowest temperature -25℃).
5. input two Channel solar panels at the same time.
6. This product adopts intelligent single-chip microcomputer design, and all workflows are controlled by software, which can achieve
high precision and high reliability.
7. The charging mode of high-efficiency MPPT is adopted to ensure that the battery works in the best state and greatly prolong the
service life of the battery.
8. It has full automatic control such as overcharge, overdischarge, overload protection, anti-reverse protection and so on
Attentions
The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages, It shall be used
with vented or sealed (VRLA) lead acid batteries only.
Safety Recommendations:
1.Batteries store a large amount of energy. Never short circuit a battery whatever.
2.Batteries can produce flammable gases. Avoid making sparks, using fire or any naked flame. Make sure that the battery
room is ventilated.
3.Avoid touching or short circuiting wires and terminals. Be aware that the voltages on specific terminals and wires can
be up to double of battery voltage. Use isolated tools. Stand on dry ground and keep your hands dry.
Installation
23 2
MPPT
Solar Charge Controller
USER MANUAL
M4860ADS
5 0
2 05
8 7. 5
Thank you very much for buying our product ,Please read
thoroughly before using the prouuct
Please installed in the room, avoiding direct-clearance,
do not install in the wet environment, when use it outdoor,
please install controller and batteries in the same place,
and the batteries installed in the same place, the controller
can measuring the battery temperature, charge
voltage regulation.
Attention:
1. Screws specifications M4
2. Make sure heat-location were not l blocke

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M4860ADS and is the answer not in the manual?

Questions and answers

Summary of Contents for MPPT M4860ADS

  • Page 1 6. This product adopts intelligent single-chip microcomputer design, and all workflows are controlled by software, which can achieve high precision and high reliability. 7. The charging mode of high-efficiency MPPT is adopted to ensure that the battery works in the best state and greatly prolong the service life of the battery.
  • Page 2 ■Input solar panel matrix power 1. the MPPT solar controller has the function of simultaneous input of two solar panels. In theory, the two solar panels can input different open circuit voltages and different power, and both can work normally. however, in order to balance the overcurrent inside the controller, it is strongly recommended that the solar panels of the same specification be used in both ways, which is beneficial to the service life and efficiency of the controller.
  • Page 3: Installation Instructions

    Installation instructions ! Warning 1 .The wiring order must be in the prescribed order, first connect the battery, and then connect the solar panel. when you disconnect the controller you must first disconnect the solar panel. then disconnect the battery, and the two groups of solar panels are in no order.
  • Page 4: Key Function

    Operation instruction Key function Forward or Increase Backward or Reduce Setting or Enter Load ON/OFF or Ese Es c Es c Icon description Solar panel voltage > light control voltage, which means daytime. Solar panel voltage > light control voltage, which means at night Charging, horizontal stripes rolling up dynamically Load ON Load OFF...
  • Page 5: Setting Battery Type

    Parameter setting operation In the battery voltage display interface, press the K3 button for 5 seconds to enter the parameter setting browsing interface (see < Parameter Settings Interface Browse >), and press K1 or K2 to cycle to the parameter interface you want to set. Short press K3 button (SET), display "SET"...
  • Page 6 Set load working mode There are 5 load working modes: 1: manual mode: press the K4 button to turn the load output on or off. 2: pure light control mode: the voltage of the solar panel is detected automatically, the load is turned on at dark and the load is turned off at dawn.
  • Page 7 Set real-time time Real-time time can be stored inside the controller, which can be kept consistent with the real time even if the controller is powered off, using load single-period control and dual-period control mode must be set to the correct real-time time. Real-time "SET","H"flash set hours...
  • Page 8: Led Status

    LED status Load status LED(Red) ON: Load on load status(red) OFF:Load off charge status ( green) Charge status(green) ON: Charging OFF:no charging fasht flash:Charging at constant voltage slow flash: Floating charging Error code When the following error occurs in the controller, the E01-E08 error code is displayed, and the buzzer alarms synchronously, and the alarm continues until the error is corrected.
  • Page 9 Parameter Note: the parameters in the following table are 12V, 24V, 36V, 48V need to be multiplied by multiple. Model M4860ADS System voltage 12V/24V/36V/48V Max.charge current 60A, 30A per channel Max. input power of solar panel 12V:780W, 24V: 1560W, 36V: 2340W, 48V:3120W 150V(At the lowest temperature) , 138V(25℃)

Table of Contents