Miscellaneous Maintenance; Checking The Nozzle - Toro Pro Force 44554 Operator's Manual

Debris blower
Hide thumbs Also See for Pro Force 44554:
Table of Contents

Advertisement

Miscellaneous
Maintenance

Checking the Nozzle

Service Interval: Before each use or daily
Checking the Nozzle Clamp
Check the nozzle clamp
it is tight. If the nozzle is dragged over obstacles or
through low areas in the terrain it could be knocked
loose from the clamp. Torque the clamp fasteners to
5.1-5.7 N⋅m (45-50 in-lb).
Figure 29
1. Nozzle clamp
(Figure
29) daily to assure
Cleaning the Nozzle Guides
Check and remove any grass, dirt or debris buildup
around and in between the nozzle guides
If the nozzle guides for the belts or rollers are not kept
free of debris, the nozzle may not rotate freely which
could cause the motor to stall.
1. Nozzle guide for rollers
2. Nozzle guide for belt
g008799
29
(Figure
Figure 30
3. Nozzle guide roller
30).
g375235