Page 1
User Manual CMP-200 Date: March 2020 Doc Version: 1.1 English Thank you for choosing our product. Please read the instructions carefully before operation. Follow these instructions to ensure that the product is functioning properly. The images shown in this manual are for illustrative purposes only.
1 Product Introduction CMP-200 series automatic barrier gate is a new barrier gate product combined with the practical application of automatic barrier gate products in the industry. Its appearance and structure design follows the needs of the market and industry, and the traffic light indication has the humanized experience.
L: The cabinet on the left R: The cabinet on the right 3 Product Installation 3.1 Installation Precautions Install the parking barrier on a level ground. If the ground is not solid and level, a cement base is needed before installation. The boom can be cut, but cannot be increased.
the spring balance needs to be set again to achieve new balance. Two plastic nuts lie in the bottom of the spring is designed for adjusting new balance. Do not change the wire connection inside when power on. The GND should be connected to the cabinet for secure protection. 3.2 Cable Embedding Prepare φ25 protective sleeve and cable in advance.
3.3 Boom Installation Boom Installation Procedure Pull the vice boom out from the main boom, then fastened by 2 screws, as shown in Figure 1. Installing the boom to the chassis, as shown in Figure 2. Figure 1 Connect the main boom with vice together by 2 screws Figure 2 Installing the Boom to the Chassis - 4 -...
4 Parameters Power adaptability Input voltage AC 220V/110V±20%, 50/60Hz Rated power 100W Max power 120W Remote control Open field≤30m distance Remote control 430MHZ, Learning code frequency Chassis material Cold gadolinium steel plate Boom material Aluminum Working -25℃~+75℃ temperature Working humidity <90%RH (no condensation) Protection grade IP54...
Chassis gross weight 47KG Telescopic straight boom, boom length≤4.5m, red and Boom type white color, the rise/fall speed is 3s (The mainboard is Telescopic straight boom, boom length: 4.5m~6m, red and the same) white color, the rise/fall speed is 6s 5 Functions The opening and closing angle is 90°±2°.
7 Control Board Wiring Installation Remove the wiring cover of the barrier gate main controller. Refer to the wiring diagram of the barrier gate controller and connect the lines one by one firmly. (Note: Power must be disconnected before installation or maintenance.) After checking and confirming reliable wiring, install the wiring cover back.
Page 12
Connection with LPR camera: Connection with UHF controller (Note: The Reader1 and 2 of inbio260 controller are corresponding to LOCK1, Reader3 and 4 are corresponding to LOCK2): - 10 -...
Page 13
Connection with loop detector: Connection with infrared detector: - 11 -...
8 Commisioning Instructions Check all the connections and make sure the connections are correct before connecting the power. Please use the remote control or press the switch button on the mainboard to test whether the machine is running normally. Warning: Be sure to install the corresponding length of boom before power-on test.
Page 15
Barrier gate Hall limit switch adjustment: Left and right movement interchange method: Barrier gate spring and boom length type matching: - 13 -...
Page 16
Study/delete remote control code Study code: In the stop state, press the “Study” button on the main controller until the REMOTE indicator is on then release it, press any button on the remote control, the REMOTE indicator is off, and the code studying is completed. Delete code: In the stop state, press the “Study”...
9 Troubleshooting Troubles Fault cause Solution 1. Connect the 1. The power supply is The POWER indicator is not on, power. not connected. the button is not responding. 2. Replace the 2. The fuse blew. fuse. 1. Remote control 1. Recode. code is wrong.
2. Replace limit switch. 1. The battery of the 1. Replace battery. Remote control handle is not handle is low. 2. Replace the responding. 2. Handle broken. handle. 10 Packing List 1) The barrier gate*1 2) The boom*1 3) The remote control*2 4) The barrier fixed screw*4 5) The boom fixed plate*1 6) The boom fixed screw*2...