CHARGING SYSTEM
Check the following before troubleshooting:
- Faulty battery
- Loose terminal connectors.
3 A charge coil type:
Check the main fuse (5
A)(P. 5-7)
Normal
Check the charge/lamp coil
Normal
Check the following:
-Circuit protector
(P. 5-9)
-Silicon rectifier
(P. 5-9)
-Regulator/rectifier
(P. 5-10)
Normal
Check the harness connecting the
charge coil for an open or short circuit,
and for proper connection. If necessary,
replace the harness.
gx120k1_gx160k1_gx200
(P.
8-5).
Abnormal
Replace the main fuse (5 A)
Abnormal
Replace the charge/lamp coil
Replace the faulty part(s)
Abnormal
-Circuit protector
-Silicon rectifier
-Regulator/rectifier
SERVICE INFORMATION
(P.
5-7).
(P.
8-2).
(P.
5-7).
2-17