Position the grill on the inside bodyface side and
fasten using the bolts, washers and nuts provided
(2 per side) as shown in the diagrams.
Note: The grill has a front and rear, the holes
on the front side have rounded edges
and the rear holes have fl at edges.
MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES
f i r e - p a r t s . c o m
The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.
Adjacent
Unit
Side Wall
(to Side)
A
Small Flush
Insert (I1100S) 15"/380mm
Large Flush
Insert (I3100L) 13"/330mm
Hearth Heater
(H2100M)
10"/255mm
Side and Top facing is a maximum of 1.5"
thick.
Floor protection must non-combustible, insula-
tive material with an R value of 1.1 or greater.
*
If the hearth extension is fl ush with the fl oor
(F) it must extend 19.5" in front of the body
face (E).
Note: Hearth Extension Width (G) is meas-
ured from edge of fuel door to side
of hearth.
** A non-combustible mantel may be in-
stalled at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Regency Wood Insert & Hearth Heater
View from Rear of Insert
Mantle**
Top
(to Top)
Facing
(to Top)
B
C
20"/510mm
14"/355mm
19"/480mm
18"/455mm
25"/635 mm
14"/355mm
The optional Flue Connector Kit (Part # 846-527)
and the Straight Flue Adaptor (Part #846-504)
shown here, may be used to produce a secure
connection between your fl ue connector and the
insert collar. Detailed installation instructions are
included with the kit.
Side
Minimum
Facing
Hearth
(to Side)
Extension*
D
E
7.375"/187mm 16"/406mm
6.5"/165mm
16"/406mm
8.5"/216mm
18"/455mm
Clearance diagram for installations
INSTALLATION
OPTIONAL FLUE
CONNECTOR KIT
Minimum
Minimum
Hearth
Hearth Side
Thickness*
Extension
F
G
1.5"/38mm
8"/205mm
1.5"/38mm
8"/205mm
1.5"/38mm
6"/152mm
7