Removal And Replacement Of Fan Motor; Removal And Replacement Of Inlet Water Valve - Hoshizaki KM-1601SWH Service Manual

Stackable crescent cuber
Hide thumbs Also See for KM-1601SWH:
Table of Contents

Advertisement

J. Removal and Replacement of Fan Motor
Note: When replacing a fan motor with defective winding, it is recommended that a new
capacitor be installed.
1) Turn off the power supply.
2) Remove the panels.
3) Remove the junction box cover from the remote condenser unit (remote air-cooled
model).
4) Remove the closed end connectors from the fan motor leads.
5) Remove the fan motor bracket and fan motor.
6) Install the new fan motor and replace the removed parts in the reverse order of which
they were removed.
7) Replace the panels in their correct positions.
8) Replace the junction box cover in its correct position (remote air-cooled model).
9) Turn on the power supply.
K. Removal and Replacement of Inlet Water Valve
1) Turn off the power supply.
2) Close the icemaker water supply line shut-off valve, then open the icemaker water
supply line drain valve.
3) Remove the front panel.
4) Remove the valve outlet tubing by releasing the clamp.
5) Loosen the fitting nut. Be careful not to lose the washer.
6) Disconnect the terminals from the water valve.
7) Remove bracket and valve from the unit.
8) Remove the valve from the bracket. Attach new valve to the bracket, then install the
valve.
9) Replace the removed parts in the reverse order of which they were removed. Make sure
the washer is in place in the fitting nut.
10) Close the icemaker water supply line drain valve, then open the icemaker water supply
line shut-off valve.
11) Turn on the power supply.
12) Check for leaks.
13) Replace the front panel in its correct position.


Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-1601swh3Km-1601srhKm-1601srh3

Table of Contents