TECHNICAL DATA

Maximum measurement depth:
Ferromagnetic metals
Non-ferrous metals (copper)
Electric wires (AC)
Wooden profiles
Maximum depth of humidity measurement 8 mm
Range / accuracy of humidity measurement
Wooden profiles
Construction Materials
Automatic shutdown
Working humidity range:
Metal
Wood
Electric wires
Working temperature
Storage temperature
Batteries
Working time
Device size

DEVICE USAGE

Installing batteries
Use only 2 x 1,5V AAA batteries.
Install the batteries by removing the battery cover 9 in the diagram.
If you do not use the device for a long time, remove the battery. After long-term use, the battery will be discharged.
Detection results depend on the size and material of the object to be detected, as well as the material and condition of the
surface and other factors. If the cable is not live, the detection depth will be lower.
WARNING!
• Do not allow moisture to enter the unit, do not expose it to direct sunlight.
• If the device is exposed to a very low temperature, wait until the device temperature rises before using it.
• When using or operating a transmitting device such as a microwave oven near the detector, this will affect the detection
results.
• In general, the detection results will be influenced by certain environmental factors. Devices that generate a strong magnetic
or electromagnetic field in the vicinity interfere with the detector. In addition, moisture, metal building materials, aluminium
cladding made of insulating materials impact the measurement. The conductivity of the wallpaper, rug or tile will affect the
detection result. Before drilling the ceiling and floor, sawing, pay attention to external factors (such as building structure).
For the best scanning result:
- Avoid wearing rings or watches when using the detector. Metal can cause inaccurate testing.
- Move the tool evenly across the surface without lifting it or changing the pressure applied.
- The tool must always touch the surface during the scan.
- Make sure that the fingers of the hand holding the tool do not touch the scanned surface.
- Do not touch the detector surface or scan with your other hand or any other part of your body.
- Always test slowly for maximum accuracy and sensitivity.

SWITCHING THE DEVICE ON/OFF

Make sure that the sensor is not damp before use. If necessary, wipe it dry with a cloth.
Press the ON/OFF button 1 in the diagram to start the unit:
After a short period of automatic testing the probe is ready for operation. The device automatically switches to metal detection
mode. At this point, if a signal is displayed in area „j" on the display screen even though there are no metal objects near the
sensor, this means that calibration is required.
THE CALIBRATION METHOD:
Place the device in an environment away from metal and strong magnetic field disturbances (e.g. by lifting the device up into the
air), and then press and hold the metal detection button 4 until in area "j" on the display screen the signal shows zero and the
green indicator light comes on. Then the calibration is complete. Release the button at this point and you can proceed to metal
detection.
Adres producenta/ Adresse des Herstellers/ Manufacturer's Address/ Адрес производителя
GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków
60 mm
50 mm
50 mm
exact mode 20 mm/deep mode 38 mm
5%-50%/±2%
1.5%-33%/±2%
after about 5 min.
0-85% RH
0-60% RH
0-30% RH
-10˚C +50˚C
-20˚C +70˚C
2 x 1.5 V AAA
6 h
134.5 x 60 x 25 mm