Calibration Of Temperature Sensor; Reset The Service Interval - Electrolux Boiling pan Smart Service Manual

Table of Contents

Advertisement

Calibration of temperature sensor

NOTE! In case of replacement of effect- or display PCB, the
food temperature sensor or the heating element temperature
sensor, temerature values for food and heating elemet have to
be calibrated as follows:
1. Fill up the boiling pan with appr. 10 cm water.
·
Press Menu forwards
for 5 seconds.
· Digit the code 1122 by pressing Increase value
crease value
for digits, and Menu forwards
back
for the position.
· Confirm by pressing Start
SAFETY TEST MODE
· Select SERVICE MODE, pressing Decrease value
press Menu forwards
SERVICE
JACKET TEMP
CALIBRATED
2. Press Decrease value
temperature sensor at -8°C.
3. Press Menu back
.
SERVICE
FOOD TEMP
CALIBRATED
· Press Decrease value
sensor at -3°C.
4. Press Start
.
· Stir the water inside the pan with a wooden ladle.
· Boiling process starts. When the water inside the pan is
boiling, the display shall indicate 100°C. Calibrate the value
by pressing Increase value
±8°C.
· Press Stop
.
· Press Menu forwards
· The boiling pan`s manometer have to show appr. 100-110
kPa (1,0-1,1 bar) when the display indicates 121°C. Calibrate
the value by pressing Increase value
max ±8°C.
·
Press Stop
.
· End the process by switching off the power, pressing ON/
OFF
.
and Menu back
simultaneously
or Menu
.
twice.
XX°C
X°C
and adjust the heating element
XX°C
X°C
and adjust the food temperature
or Decrease value
once and Press Start
.
or Decrease value
Adjustment of the jacket cooling water
Valid to
june
1. Start the automatic cooling program, vait until a uniform
flow of water running out of both pipes.
2. Put a bucket under båth pipes and fill under 20 seconds.
3. messure the water and confer with the tabe below:
or De-
Size(L)
50-100
150
200-300
Adjust with radiator filler neck.
and
max.
Reset the service intervall
Resetting the service interval after completion of service in
order to change the message in the display.
Press Menu forwards
for 5 seconds.
Digit the code 1122 by pressing Increase value
crease value
back
for the position.
· Confirm by pressing Start
• Select SERVICE MODE, pressing Decrease value
press Menu forwards
TIME TO SERVICE
0000
The time shown is the number of hours which elapsed since
the latest service and the maintenance interval.
• To reset the counter, press Stop
• End the process by switching off the power, pressing ON/
OFF
.
2013.
Flow (l/min.)
Flow (l/20 sec.)
10
11
12
Radiator filler neck
and Menu back
for digits, and Menu forwards
.
.
(0000) H
in 3 sec.
3,3
3,7
4
simultaneously
or De-
or Menu
and
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart variomixSmart promix

Table of Contents