Reverse EU Siren Interlock Function Programming

To interlock buttons between primary and secondary button.
- the secondary button will now activate when primary button is enabled.
Function
- the primary button will be disabled when secondary button is disabled.
- the user may still disable the primary button on its own command.
- Push C1 and C4 together for 5 seconds to enter Siren Interlock Programming mode. L3
and L8 will be solid to indicate you are now in programming mode.
- Press once on the selected button to set functions for interlock. The Red LED backlight
will indicate your setting for the button.
- Push C1 and C5 together for 5 seconds to exit the programming mode.

EU Siren Interlock Function Programming

To interlock buttons between primary and secondary button.
- the secondary button will now activate when primary button is enabled.
- the secondary button will be disabled when primary button is disabled.
Function
- the secondary button can not be enabled without the activation of primary
button.
- the user may still disable the secondary button on its own command.
- Push C1 and C5 together for 5 seconds to enter Siren Interlock Programming mode. L3
and L8 will be solid to indicate you are now in programming mode.
- Press once on the selected button to set functions for interlock. The Red LED backlight
will indicate your setting for the button.
- Push C1 and C5 together for 5 seconds to exit the programming mode.
ON
Set as Master
Rapid Flashing
Set as Master
RED LED Backlight Status
Flashing
Set as Slave
RED LED Backlight Status
Slow Flashing
Set as Slave
- 3 -
OFF
No Interlock Setting
OFF
No Interlock Setting