7.
EDID
Select the device ID, then click "Get EDID", you will see HDMI Decoder EDID,
and Monitor EDID. Then select EDID you want to save and click "Save EDID".
Next, click "Upload EDID" and choose EDID file to learn EDID. Users can also
click "View" to check EDID description.
8.
Firmware Update
–
Firmware Update Process
I. Click "Browse" to select the file which you want to write into device.
II. Select the output device which you want to update.
III. Click "Start" and firmware will start to update.
IV. After updating, please right-click on device ID and select "Factory Reset".
V. Power cycle the device.
* Please save the firmware file (.bin) & software in the same folder.
–
Device Mode
Transmitter: set the device as the transmitter
Receiver: set the device as the receiver
Transceiver: set the device as the transceiver
VEGA-1100 User Manual
18