redundancy checks.
age1439_fiber_crc_get
(on page 112)
check setting.
age1439_fiber_error_clear
age1439_fiber_error_get
ister.
age1439_fiber_flow_control
disabling transmitter flow control signals.
age1439_fiber_flow_control_get
flow control function.
age1439_fiber_LED_get
front panel XMT/RCV led's.
age1439_fiber_mode
(on page 112)
age1439_fiber_mode_get
age1439_fiber_rcv_signals_get
DIR and NRDY bits from the fiber receiver.
age1439_fiber_setup
(on page 112)
face.
age1439_fiber_signal_get
optical signal is detected by the optical fiber interface receiver.
age1439_fiber_transfer_rate
age1439_fiber_transfer_rate_get
rate for fiber optic data.
age1439_fiber_verify
(on page 116)
either an internal of external signal path.
age1439_fiber_xmt_BOF
with other fiber interfaces before data acquisition begins.
age1439_fiber_xmt_signals
PIO2, DIR or, NRDY FPDP control signals on the fiber transmitter
age1439_fiber_xmt_signals_get
PIO2, DIR and NRDY bits from the fiber transmitter.
age1439_epoch_generate
ated.
age1439_epoch_generate_get
age1439_epoch_header
(on page 98)
header. It can be used by the optical receiver to direct where to route and/or how to
process associated epoch data.
age1439_epoch_header_get
increment count for the epoch header.
age1439_epoch_header_enable
generated
age1439_epoch_header_enable_get
enable.
age1439_epoch_setup
(on page 98)
data epochs on the fiber interface.
age1439_epoch_size
(on page 98)
age1439_epoch_size_get
interface
Agilent E1439 Programmer's Reference
−returns the current status of the cyclic redundancy
(on page
107)−clears fiber errors from the status register
−returns the value of the fiber interface error reg-
(on page 108)
−configures fiber flow control, enabling or
(on page 112)
−returns the current status of the fiber
(on page 112)
−returns a data register indicating the state of the
(on page 110)
−selects the fiber interface mode.
−gets the current mode of the fiber interface.
(on page 112)
−displays the current value of PIO1, PIO2,
(on page 111)
−sets the parameters associated with the fiber inter-
−returns a value indicating whether or not an
(on page 115)
−selects the transfer rate for fiber optic data.
(on page 112)
−gets the current selection of transfer
(on page 112)
−proforms a verification of the fiber interface using
−sends a BOF event used for synchronization
(on page 117)
−sets the transmitted values of any PIO1,
(on page 118)
−displays the current value of PIO1,
(on page 118)
−controls whether or not data epochs are gener-
(on page 98)
− gets the current value of epochGenerate
(on page 98)
−sets the value of the first 32 bits of the epoch
− returns the header value and the value of the
(on page 98)
− controls whether or not epoch headers are
(on page 98)
−returns the current value of header
(on page 98)
−sets the parameters relevant to the transmission of
−sets the size of data epochs in bytes.
−returns the current size of data epochs on the fiber
(on page 98)
Functions listed by functional group
63