Data Format - Agilent Technologies E1439 User Manual

Vxi 70 mhz if adc with filters and memory
Table of Contents

Advertisement

Initializing and closing
age1439_init
(on page 132)
age1439_close
(on page 86)
Analog setup
age1439_input_setup
(on page 141)
age1439_input_alias_filter
age1439_input_alias_filter_get
age1439_input_autozero
age1439_input_coupling
age1439_input_coupling_get
age1439_input_offset
(on page 135)
age1439_input_offset_get
age1439_input_offset_save
age1439_input_range
(on page 141)
age1439_input_range_auto
age1439_input_range_convert
age1439_input_range_get
age1439_input_signal_path
age1439_input_signal_path_get
age1439_input_signal
(on page 141)
fier
age1439_input_signal_get
age1439_state_save
(on page 175)
age1439_state_recall
(on page 174)

Data format

age1439_data_setup
(on page 90)
age1439_data_blocksize
age1439_data_blocksize_get
age1439_data_delay
(on page 90)
age1439_data_delay_get
age1439_data_memsize_get
age1439_data_mode
(on page 90)
age1439_data_mode_get
age1439_data_port
(on page 90)
transmission
age1439_data_port_get
age1439_data_resolution
age1439_data_resolution_get
age1439_data_scale_get
volts
age1439_data_type
(on page 90)
age1439_data_type_get
age1439_data_spectral_order −specifies the spectral order of the output data.
age1439_data_spectral_order_get −gets the spectral order of the output data.
age1439_data_xfersize
entire block has been acquired.
age1439_data_xfersize_get
−initializes the I/O driver for a module
−closes the module's software connection
−sets all the analog input parameters
−include/bypass the built-in analog anti-alias filter
(on page 141)
−gets the anti-alias filter state
(on page 141)
−nulls out the input dc offset in baseband mode
(on page 141)
−selects ac or dc input coupling
(on page 141)
−get the input coupling type
(on page 141)
−sets the dc offset settings for the current range
−gets the dc offset settings
(on page 135)
−saves the dc offset settings in NVRAM
(on page 136)
−sets the full scale input range
−performs auto-ranging
(on page 137)
−converts input range to volts
(on page 138)
−gets the input range
(on page 141)
−selects baseband or IF signal path
(on page 141)
−gets the signal path state
(on page 141)
−connect/disconnect the input signal to the input ampli-
−gets the input buffer amplifier state
(on page 141)
−saves the current module state
−recalls a previous module state
−sets all format and data output flow parameters
−determines the size of the output data block
(on page 90)
−gets the output data block size
(on page 90)
−determines FIFO delay in continuous mode
−gets FIFO delay
(on page 90)
−returns module's memory size
(on page 88)
−selects block mode or continuous mode
−gets the data mode
(on page 90)
−selects VME bus, local bus or fiber interface for output
−gets the output port designation
(on page 90)
−selects 12 or 24 bits data resolution
(on page 90)
−gets the data resolution
(on page 90)
−gets the data scale factor used to convert raw data to
(on page 89)
−selects real or complex output data
−gets output data type
(on page 90)
−allows a specified amount of data to be read before an
(on page 96)
−gets the data transfer size
(on page 96)
Agilent E1439 Programmer's Reference
Functions listed by functional group
61

Advertisement

Table of Contents
loading

Table of Contents

Save Article as PDF