PTO™ MOD3

Charge Blockout

This function prevents the charger from charging the battery during the block out time window. If a charge
cycle has started before the block out window it is inhibited during the block out window and will automatically
restart the charge cycle at the end of the block out window.

Charging Profile

The charging profile defines the rate of current charge over time. The charger adapts to the battery's condition
and level of discharge.

Cold Profile

This is a charging profile that allows the configuration of the charger for use with batteries in cold storage
application. The profile is an IEI (constant current, constant voltage, constant current) type with a number of
user configurable parameters.
Thin Plate Pure Lead (TPPL)
This is an advanced lead acid battery design used in FLEX batteries. TPPL technology provides longer
service life, higher power density, longer shelf life and fast recharge capabilities.

Flex Bloc Profile

This charging profile allows charging of Flex bloc batteries at rates up to 0.7C.

Flex Standard Profile

This charging profile allows charging of FLEX 2v cell batteries at rates up to 0.25C.

Equalization Charging

Equalization charging, performed after normal charging, balances the electrolyte densities in the battery's
cells.

Opportunity Profile

The OPPOR charge profile is used when opportunity charging is desired. It has a start rate of 25% of the
batteries rated amp hour capacity, requires one complete recharge in every 24 hours of service and must
have an equalize charge done once a week which is programmed to run automatically.
Operation:
During opportunity charging the user can plug the battery in and charge it during breaks, lunch or any
work stoppage time. One time per day the battery must receive a full standard recharge. The complete
charge must be programmed for a delay that's long enough so that the complete charge will not occur
during normal operation. Sufficient time should be scheduled after the full charge to allow the battery
to completely cool to ambient temperatures before use.
Note: The user must configure the charger for the day of the week that the equalize charge will take
place.

Standard Flooded

The profile is an IEI (constant current, constant voltage, constant current) type with a number of user
configurable parameters.

Refresh Charging

Refresh or maintenance charging enables the battery to be maintained at maximum charge all the time that
it is connected to the charger. Refresh charge is applied at a predetermined intervals after charge is complete
and battery remains connected to charger.
Owner's Manual

GLOSSARY

10
AM-HPTOM3-OM
Rev AB February 2020