Thermia AB is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions. Other languages are a translation of the original instructions. (Directive 2006/42/EC)
Technical description Athena 1.1.2 Indoor unit Indoor unit Athena Total 300L 1a. Hot water line, 22 mm 1b. Cold water line, 22 mm 2a. Heating system supply, 28 mm 2b. Heating system return, 28 mm 3. Connection for bleed valve, 28 mm 4a.
Page 6
Technical description Athena Indoor unit Athena Compact 1a. Hot water line, 22 mm 1b. Cold water line, 22 mm 2a. Heating system supply, 28 mm 2b. Heating system return, 28 mm 3. Connection for bleed valve, 28 mm 4a. Supply line from outdoor unit, 28 mm Cu (left or right) 4b.
Page 7
Technical description Athena Indoor unit Athena Total EQ 1a. Hot water line, 22 mm 1b. Cold water line, 22 mm 2a. Heating system supply, 28 mm 2b. Heating system return, 28 mm 3. Connection for bleed valve, 28 mm 4a. Supply line from outdoor unit, 28 mm Cu (left or right) 4b.
Technical description Athena Min./max. output Athena 14 H/HC 20,00 15,00 10,00 5,00 0,00 Outdoor temperature [˚C] max W55 max W65 max W35 max W45 min W65 min W55 min W45 min W35 AWAT01TD0102 Thermia AB...
Technical description Athena Min./max. output Athena 18 H/HC 20,00 15,00 10,00 5,00 0,00 Outdoor temperature [˚C] max W55 max W65 max W35 max W45 min W65 min W55 min W45 min W35 AWAT01TD0102 Thermia AB...
SETTINGS - Circulation pumps - Condenser pump HP - Min speed. Adjust the minimum speed of the condenser pump in order to have at least approximately 18 l/min. Pressure loss - Athena Internal pressure loss in Athena outdoor unit. Thermia AB AWAT01TD0102...
Page 14
Total pressure loss in the heating system with outdoor unit and respective indoor unit. The pressure loss in the heating system has been calculated according to an assumed standard installation consisting of Athena outdoor units, indoor units (Total EQ/Total 300L/Compact), 10m copper pipes (Ø 28mm) and minor losses corresponding to 90° bends.
Page 15
Total EQ Compact External available pressure with internal circulation pump for Athena. When calculating the available pressure for Total EQ, the internal pressure loss was taken into account due to its two circulation pumps, where one works towards the rad system. For Total 300L and Compact, the total pressure in the heating system was considered.
Technical description Athena Fan speeds Athena H/HC In heating mode the fan speed increases with decreasing outdoor temperature, as shown in the table above. Recommended outdoor unit placement Avoid placing the outdoor unit close to bedroom or living room windows. Preferable placement is instead on solid walls facing away from any close neighbouring houses or facilities.
Page 17
Technical description Athena Thermia AB AWAT01TD0102...
Page 19
Technical description Athena Thermia AB AWAT01TD0102...
Page 20
Thermia can accept no responsibility for possible errors in catalogues, brochures and other printed material. Thermia reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.