STEP 9:
END STOP INSTALLATION
4-5/8" THRU 5-1/4"
5-1/2" THRU 6-3/4"
BRIDGE BEAM
A
FLANGE WIDTH
3-3/8"
2"
3-5/8" THRU 4"
2-1/4"
2-3/4"
3-1/2"
7" THRU 7-5/8"
4"
IMPROPERLY INSTALLED TROLLEY STOPS (CLIPS ANGLES) CAN
RESULT IN LOSS OF BRIDGE WITH RESULTANT INJURY AND DAMAGE.
INSTALL END STOPS ON BOTH ENDS OF BEAMS TO PREVENT HOIST
TROLLEY STOP
ANGLE SIZE*
(4 REQ'D.)
3 x 3 x 3/8
3-1/2 x 3 x 3/8
4 x 3 x 3/8
5 x 3 x 3/8
6 x 3 x 3/8
WARNING
TO AVOID INJURY AND DAMAGE:
TROLLEY FROM RUNNING OFF END OF BEAM.
29
B
C
1"
2"
1"
3"
1-1/2"
3"
1-3/4"
3"
1-3/4"
4"
P/N: C11746310 REV. AB June 2022
D
4"
5"
5"
5"
6"

Advertisement