Download Print this page
F&F PK-1Z-LED 230 V Manual

F&F PK-1Z-LED 230 V Manual

Electromagnetic relay

Advertisement

Quick Links

PK-1Z-LED
Electromagnetic
Do not dispose of this device in the trash along with other waste!
According to the Law on Waste, electro coming from households free of charge and can
give any amount to up to that end point of collection, as well as to store the occasion of
the purchase of new equipment (in accordance with the principle of old-for-new, regard-
less of brand). Electro thrown in the trash or abandoned in nature, pose a threat to the
environment and human health.
Purpose
Electromagnetic relay in a single-module housing for direct mo-
unting on the TH-35 rail.
The "LED" version of the relay is equipped with a contact
designed to cooperate with receivers with high starting
current, such as: LED fluorescent lamps, ESL fluorescent
lamps, electronic transformers, discharge lamps, etc.
Functioning
Applying the supply voltage to the relay coil will switch the con-
tacts to the position 11-12. This state is indicated by a green LED.
After a power failure, the contacts return to position 11-10.
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
230 V
relay
- 1 -

Advertisement

loading

Summary of Contents for F&F PK-1Z-LED 230 V

  • Page 1 F&F Filipowski sp. j. Konstantynowska 79/81, 95-200 Pabianice, POLAND phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71 www.fif.com.pl; e-mail: biuro@fif.com.pl PK-1Z-LED 230 V Electromagnetic relay Do not dispose of this device in the trash along with other waste! According to the Law on Waste, electro coming from households free of charge and can give any amount to up to that end point of collection, as well as to store the occasion of the purchase of new equipment (in accordance with the principle of old-for-new, regard-...
  • Page 2 Mounting 1. Disconnect the power supply. 2. Fix the relay on the rail in the distribution box. 3. Connect the power supply to terminals 1-3 (any order). 4. Power supply circuit of controlled receiver's connect by con- tacts 11-12 (NO contact). Wiring diagram power supply 230 V AC 11-12...
  • Page 3 Technical data power supply 230 V AC maximum load current (AC-1) 16 A* switching voltage 250 V AC contact separated 1×NO (120 A/20 ms) usage category AC-7a insulation voltage 400 V surge voltage contacts-coil 2.5 kV contact separation 1.2 kV surge resistance 3 kV current consumption...
  • Page 4 Power table Table for loads supplied with 230 V AC: tungsten halogen fluorescent energy-saving 3000 W 2500 W 1500 W 750 W 750 W The above data are indicative and will heavily depend on the design of a specific receiver (that is especially important for LED bulbs, energy-saving lamps, electronic transformers and pulse power supply units), switching frequency and operating conditions.

This manual is also suitable for:

Pk-1z-led5902431674735