Purpose
Electromagnetic relay in a single-module housing for direct mo-
unting on the TH-35 rail.
The "LED" version of the relay is equipped with a contact
designed to cooperate with receivers with high starting
current, such as: LED fluorescent lamps, ESL fluorescent
lamps, electronic transformers, discharge lamps, etc.
Functioning
Applying the supply voltage to the relay coil will close the con-
tact 1 between terminals 8-9 and the contact 2 between termi-
nals 11-12. This state is indicated by a green LED. After a power
failure, the both contacts open.
F&F Filipowski sp. j.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
24 V
relay
- 1 -

Advertisement

loading

Summary of Contents for F&F PK-2Z-LED 24 V

  • Page 1 F&F Filipowski sp. j. Konstantynowska 79/81, 95-200 Pabianice, POLAND phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71 www.fif.com.pl; e-mail: biuro@fif.com.pl PK-2Z-LED 24 V Electromagnetic relay Do not dispose of this device in the trash along with other waste! According to the Law on Waste, electro coming from households free of charge and can give any amount to up to that end point of collection, as well as to store the occasion of the purchase of new equipment (in accordance with the principle of old-for-new, regard-...
  • Page 2 Mounting 1. Disconnect the power supply. 2. Fix the relay on the rail in the distribution box. 3. Connect the power supply to terminals 1-3. 4. Contacts (8-9 and 11-12) should be connected as provided for function for them (2×NO contact). Wiring diagram power supply 24 V AC/DC NO contact 1...
  • Page 3 Technical data power supply 24 V AC/DC maximum load current (AC-1) 16 A (120 A/20 ms)* switching voltage 250 V AC contact separated 2×NO usage category AC-7a insulation voltage 400 V surge voltage contacts-coil 2.5 kV contact separation 1.2 kV surge resistance 3 kV current consumption...
  • Page 4 Power table Table for loads supplied with 230 V AC: tungsten halogen fluorescent energy-saving 3000 W 2500 W 1500 W 750 W 750 W The above data are indicative and will heavily depend on the design of a specific receiver (that is especially important for LED bulbs, energy-saving lamps, electronic transformers and pulse power supply units), switching frequency and operating conditions.