UBI EasyCoder 71 – Programming
TEXT & BAR CODE COMMANDS, cont'd.
B
Place Bar Code, cont'd.
Time:
TT
Places current time, (read from the RTC, if fitted), using
time layout defined.
or...
TT+nnn Places "sell by" time. Adds nnn number of minutes (must
be three digits) to the current time (read from the RTC, if
fitted), and places it on the form using time layout defined.
or...
TD
Places current date, (read from the RTC, if fitted), using
date layout defined.
or...
TD+nn
Places "sell by" date. Adds nn number of days (must be
three digits) to the current date (read from the RTC, if
fitted), and places it on the form using date layout defined.
Valid Bar Code Commands
Ba,b,c,d,e,f,g,h,"DATA"
Ba,b,c,d,e,f,g,h,Vnn
Ba,b,c,d,e,f,g,h,Cn
Ba,b,c,d,e,f,g,h,TT
Ba,b,c,d,e,f,g,h,TT+015
Ba,b,c,d,e,f,g,h,TD
Ba,b,c,d,e,f,g,h,TD+05
or a combination thereof:
Ba,b,c,d,e,f,g,h,"DATA"V00C0"DATA"TDV01TT+015
Fields in forms containing variables, counters, time and
date will not be printed, unless a question mark (? ) is sent
after the Form Retrieve (FR) command. This does not apply
to the Direct Mode (Time and Date only).
Explanation
Write Barcode
Write Variable
Write Counter
Write Current Time
Write Current Time + 15 minutes
Write Current Date
Write "Sell By" Date
IMPORTANT!
64
Need help?
Do you have a question about the EasyCoder 71 and is the answer not in the manual?