Installation
Ribbon Low Sensor
NOTE!
The Ribbon Unwind Unit
does not need to be dismounted!
Information in this manual is subject to change without prior notice and does not represent a commitment
on the part of Intermec Printer AB.
© Copyright Intermec PTC AB 1998. All rights reserved. Published in Sweden.
EasyCoder and Fingerprint are registered trademarks of Intermec Technologies Corp.
Torx is a registered trademark of Camcar Division of Textron Inc.
Intermec EasyCoder 501/601 XP Ribbon Low Sensor – Installation Instructions Ed. 2
• Open the right-hand door.
• Turn off the power and remove the left-hand cover.
• From the paper compartment side, insert the connector and cable
through the square hole in the centre-line wall.
• Insert the sensor under the code disk of the ribbon unwind unit
so the disc will run in the U-shaped slot between the receiver and
transmitter. There is no need to dismount the ribbon unwind unit.
• Attach the sensor to the centre-line wall by means of one #T10
Torx screw. Check that the code disc can rotate freely.
• Connect the cable to P57 on the CPU board.
• Put back the left-hand cover.
• Turn on the power and check that the sensor works by reading
its values using the Intermec Fingerprint instruction PRINT
SYSVAR(13) while manually rotating the ribbon unwind spool.