Pelsue AC-R Series Product Manual page 19

Anchor clamps for round manways provides fall arrest tower mounting]
Table of Contents

Advertisement

6.2 - Inspection (continued)
3. Structure:
The entire product structure should be checked for cracks, gouges, dents, bends or breaks. If there are dents or
any other structural damage, the unit should be removed from service and returned to the factory for repair.
• Pay special attention to weld locations: look for cracks or separation at the welds. Keep in mind the nickel plat-
ing can age and scratch, this normal fi nish scratching can be confused with structural cracking. If there is any
uncertainty with regards to cracks, contact the Pelsue service department for assistance and/or recommenda-
tions
• Ensure that the sections of the device can freely move and be adjusted as intended without interference. Binding
or interference of any kind may be indicative of structural damage and must be cause for further inspection.
4. Threaded Adjustments:
Ensure that when turning the Hex Drive Hub or Speed Handle as well as the 4X Flange Thickness Adjustment
Knobs, that they turn freely and that their is no binding in the movement of the parts. Visually check the condition
of all of the threads on the adjustment screws. The threads must be clean, and free of any damage. If any stripped
or fl attened threads are observed anywhere on the product, it must be removed from service immediately.
501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01
Page 19

Advertisement

Table of Contents
loading

Related Products for Pelsue AC-R Series

This manual is also suitable for:

501169-001

Table of Contents