Pelsue AC-R Series Product Manual

Pelsue AC-R Series Product Manual

Anchor clamps for round manways provides fall arrest tower mounting]

Advertisement

Quick Links

Part #501169-001
Product Manual:
"AC-R" Series Anchor Clamps for Round Manways
[Provides Fall Arrest Tower Mounting]
ISO 9 00 1 Ce rtifi e d
T.A. Pelsue Company
2500 South Tejon Street
Englewood, Colorado, USA 80110
Tel. 800-525-8460 or 303-936-7432
Fax. 303-934-5581
Internet: www.pelsue.com
Email: sales@pelsue.com

Advertisement

Table of Contents
loading

Summary of Contents for Pelsue AC-R Series

  • Page 1 Part #501169-001 Product Manual: “AC-R” Series Anchor Clamps for Round Manways [Provides Fall Arrest Tower Mounting] ISO 9 00 1 Ce rtifi e d T.A. Pelsue Company 2500 South Tejon Street Englewood, Colorado, USA 80110 Tel. 800-525-8460 or 303-936-7432 Fax. 303-934-5581 Internet: www.pelsue.com...
  • Page 2 Page 2 Page 2 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 3 fi ne products for a broad spectrum of ities available, Pelsue continues the dedication that industry throughout the world. has made us pre-eminent in this fi eld. Page 3 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 4: Table Of Contents

    5.2 ......Product Installation & Set-Up 6.0........Maintenance & Inspection......18 6.1 ......Maintenance 6.2 ......Inspection 6.3......Inspection Log 7.0........Storage............22 8.0........Contact Information........22 Page 4 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 5: General Information

    EVERY T.A. PELSUE COMPANY EMPLOYEE IS EXPECTED TO COMMIT TO THIS PHILOSOPHY IN THE PERFORMANCE OF HIS OR HER DAILY TASKS. QUALITY FIRST! T.A. PELSUE COMPANY SENIOR MANAGEMENT TEAM Page 5 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 6: Pelsue Product Warranty

    • In the event of failure of any components of a Pelsue product within the warranty period, service must be pre-approved by the T.A. Pelsue Company and service must be performed by the T.A. Pelsue Com- pany Parts and Service Department in Englewood Colorado, or at the option of T.A.
  • Page 7: Introduction & Product Information

    2.0 - Introduction & Product Information Congratulations on your choice of a Pelsue AC-R Series Anchor Clamp to compliment your fall arrest system. This equipment has been designed and manufactured to exceed fall arrest requirements and regulations in order to meet the needs of the discriminating operator.
  • Page 8: Confi Guration & Assembly

    3.0 - Confi guration & Assembly Upon initial receipt of the #AC-R Series Device, inspect the packaging for any evidence that the product may have been damaged in shipment. While unpacking the product, inspect all of the components for damage. If damage to any of the components is discovered, DO NOT USE THE PRODUCT! Alert the shipping carrier immediately of the damage to the shipment.
  • Page 9: Safety

    This manual will take you step-by-step through the workings and capabilities of the AC-R Series Anchor Clamp and alert you to all good safety and operating practices while using the system.
  • Page 10: Safety Alert Symbol

    Securely anchor the product before using. Use only certifi ed anchor and connector components in your system. Use only an approved full body harness for the workers. Page 10 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 11: Maintenance Safety

    4.6 - New Operator or Owner The Pelsue AC-R Series Adjustable Anchor Clamp for Round Manways is designed as a portable Base System for a Pelsue Model #FT-C70 fall arrest tower. Every new operator must read, understand and follow the instructions in this Product Manual.
  • Page 12: Product Operation

    The Pelsue AC-R Series Anchor Clamp is constructed from carbon steel & incorporates high-strength alloy steel hard- ware. The AC-R Series Anchor Clamp is specifi cally designed to provide a compliant mounting point for a Pelsue Model #FT-C70 Fall Arrest Tower. All specifi cations, instructions, and procedures provided within this manual or upon Pelsue Specifi...
  • Page 13: Product Installation & Set-Up

    Figure #5c: AC-R Series Anchor Clamp, Testing & Loading Diagram 5.2 - Product Installation & Set-up Prior to Operation, the AC-R Series Anchor Clamp doe Round Manways must be confi gured and installed according to the following guidelines. FLANGE THICKNESS 1.
  • Page 14 “Maximum Manway Flange Outside Diameter”. This is made possible in order to facilitate the installation of the device. As a result of this construction the AC-R Series clamp CAN physi- cally mount on Manway structures which fall outside of the tabulated dimensions (refer to Table #5a).
  • Page 15 “near” contact with the fl ange should ensure that the jaws are properly positioned (refer Figure #5h: to Figure #5h for proper positioning). Installation Step “d” Page 15 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 16 3. Installation of an #FT-C70 Fall Arrest Tower on the AC-R Series Anchor Clamp: a. Install the AC-R Series Anchor Clamp according to the instructions in Step #2 of section 5.2 of this manual. b. Separate the #FT-C70 tower into its two major components (i.e.
  • Page 17 The rating of the installed tower Figure #5n: may supersede or derate the capabilities of Tower #FT-C70 Installation Step “e” the AC-R Series Clamp. Page 17 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 18: Maintenance & Inspection

    Specifi cally check for “elongation” of the pin holes in the ears. The pin holes should be round with relatively sharp edges at the face of the ear. Any AC-R Series Anchor Clamp system exhibiting deformation in the ears should be removed from service immediately.
  • Page 19 The threads must be clean, and free of any damage. If any stripped or fl attened threads are observed anywhere on the product, it must be removed from service immediately. Page 19 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 20: Inspection Log

    6.3 - Inspection Log Page 20 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 21 6.3 - Inspection Log (continued) Page 21 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 22: Storage

    For More Information... T.A. Pelsue Company 2500 S. Tejon St. Englewood, CO 80110 Toll Free: 1-800-525-8460 Telephone: 1-303-936-7432 Fax: 1-303-934-5581 Website: www.pelsue.com Email: sales@pelsue.com Page 22 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 23 Page 23 501169-001 - Product Manual - AC-R Series Anchor Clamp - Revision 00 - 2012-05-01...
  • Page 24 T.A. Pelsue Company 2500 South Tejon Street, Englewood, Colorado, USA 80110 Toll free 800-525-8460 or 303-936-7432 Fax. 303-934-5581 ISO 9001 Cer tified Internet: www.pelsue.com Email: sales@pelsue.com...

This manual is also suitable for:

501169-001

Table of Contents