3. Now you can remove the rod.
The rod can only be removed after having removed the
balancing springs.
Should the beam be damaged or broken, proceed as follows:
Use of the release device with a damaged or removed
beam can cause abrupt and uncontrolled movements,
which can cause injury to people and breaking of the
automated system. NEVER USE THE RELEASE DEVICE.
1. Cut off system power.
2. Replace the beam.
3. Ensure that the beam is correctly balanced.
4. Power the system and ensure that the automated system is
operating correctly.
10. REPAIRS
The user must not attempt any repair or job and must only and
exclusively contact qualifi ed GENIUS personnel or GENIUS ser-
vice centres.
11. ACCESSORIES
11.1. ARTICULATION KIT
IThe articulation kit, fi g. 30, was created to articulate the rigid rod
enabling installation in covered places.
If the articulation kit is used, the balancing spring must be
adapted.
11.2. SKIRT KIT
The skirt kit, fi g. 31, increases visibility of the beam. The kit is
available in lengths of 2 meters.
If the skirt kit is installed, the balancing spring must be
adapted.
11.3. END FOOT
The end foot, fi g. 32, allows the rod to rest when closed thus
preventing the profi le bending downward.
If the end foot is used, the balancing spring must be adap-
ted.
11.4. FORK SUPPORT
The fork support, fi g. 33, has two functions:
• It prevents the rod, when closed, from bending and splitting due
to external stresses.
• It allows the rod to rest when closed thus preventing any bending.
The use of the fork support does not imply any adaptation
of the balancing spring.
For the positioning of support refer to the dimensions shown
in Figure 34.
11.5. PHOTOCELL SUPPORT
The photocell support, fi g. 35, enables the positioning of a pair of
photocells aligned with the rod.
The second photocell must be positioned using a column.
11.6. LUMINOUS STRIP FOR UPRIGHT
The luminous strip for the upright increases visibility of the au-
tomated system and compensates the use of a fl ashing lamp.
Its operation is controlled by the control unit.
11.7. LUMINOUS STRIP FOR ROD
The luminous strip for rod is positioned on top of the rod to in-
crease its visibility. The operation of the strip is controlled by the
control unit.
If the luminous strip is used on the rod, the balancing spring
must be adapted.
11.8. BATTERY KIT
A tray to house buffer batteries (not supplied) is located in the
upright. For models RAINBOW 524 C and RAINBOW 524 C you
can use 24V 7Ah batteries, whereas for the RAINBOW 724 C
model you can use 24V 12Ah batteries.