Boiling pans with tilting height 600mm
Hide thumbs Also See for SMART:
Table of Contents

Advertisement

INSTALLATION INSTRUCTIONS | SmART LINE BOILINg PAN

12.6 multi stand

NOTE
Please follow these instructions
• Boiling pan with the option ice water
cooling (SV6I and SP6I) can only stand on
the far left in a multi-stand.
50L
80L
100L
N *
1245
1375
1420
r
595
763
763
Z
225
225
225
W
98
82
82
* measure N is selected according to the largest pan in the multistand
1 Fixtures: PNC 928029 (50L, 80L and 100L)
PNC 928030 (150L, 200L, 300L)
2 Alternative direction of drainag
Connections:
A Hot water: DN15 (g1/2") internal thread
B Cold water: DN20 (g3/4") male thread
C Electrical cable
H Steam connection, 110-170 kPa (1.1-1.7 bar)
Steam-heated pans: DN20 (g3/4") Internal thread
I Condensation connection (Steam-heated pans):
DN20 (g3/4") Internal thread
EN | 10-2018
150L
200L
300L
1480
1550
1600
883
927
1079
245
245
245
142
164
240
• Connections for appropriate pan in the right
• Condensation connection always in the col-
DOC N° ST0 9183-02
NOTE
Please follow these instructions
column.
umn to the left of the pan.