Trane A801X026AM2SC Installation, Operation And Maintenance Manual page 55

Upflow/downflow/horizontal left/right gas-fired, single stage induced draft furnaces with high efficiency motor
Table of Contents

Advertisement

DEFINITION
An error has occurred with the PS1, indica ng that the pressure
switch is closed when it should be open.
In most cases, the pressure switch is not the problem.
NOTE: Verify pressure switch wiring and tube rou ng
are correct.
A801X-SVX001-1A-EN
Replace pressure
NO
switch
3.1 Fault Code
Cycle power to the furnace
st
and call for 1 stage heat.
Is 24 volts present ,
measured across PS1
YES
( orange to yellow)?
See Note #1
T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g
Note #1
24 volts = Open Switch
0 volts = Closed Switch
Verify wiring. If
correct, replace IFC
55