Trane A801X026AM2SC Installation, Operation And Maintenance Manual page 32

Upflow/downflow/horizontal left/right gas-fired, single stage induced draft furnaces with high efficiency motor
Table of Contents

Advertisement

F F u u r r n n a a c c e e G G e e n n e e r r a a l l I I n n s s t t a a l l l l a a t t i i o o n n
R R e e t t u u r r n n D D u u c c t t C C o o n n n n e e c c t t i i o o n n s s
Return Ducting General Guidelines
Back returns are not allowed on any S-Series Furnaces
Side returns are not allowed on downflow or horizontal S-Series Furnaces
Mounting flanges must be located on ducting
Shoot screws through the mount flanges into the furnace cabinet
Always seal per local codes and requirements
Furnace, coil, and ducting must be supported separately
An external overflow drain pan must be installed in all applications over a finished ceiling to prevent property damage
Upflow Furnace with Bottom Return in Closet with Remote
Refer to
Step
1.,
Upflow Furnace with Bottom Return Mounted on a Ducted
Refer to
Step
1.,
I I n n s s t t a a l l l l a a t t i i o o n n I I n n s s t t r r u u c c t t i i o o n n s s
1. Remove the bottom plate.
2. Set the furnace on the base inside closet.
3. Install remote filter.
4. Set the furnace on the filter box inside closet.
5. Must have grille present for air.
32
Filter
Step
2.,
Step
3., and
Step 8.
Pedestal
Step
6.,
Step
3., and
Step 8.
Upflow Furnace with Bottom Return in Closet with Filter Box
Refer to
Step
1.,
Step
Upflow Furnace with Bottom Return Mounted on a Ducted
Pedestal with Filter Box
Refer to
Step
1.,
6. Set the furnace on the ducted pedestal. The ducted
pedestal will use ducted air from a remote location.
7. Set the furnace on the filter box. The ducted
pedestal will use ducted air from a remote location.
8. Seal per local codes and requirements.
4.,
Step
5., and
Step 8.
Step
7., and
Step 8.
A801X-SVX001-1A-EN