Label on
lower left corner
(front side)
Labels on
opposite sides
Label on
lower left corner
(rear side)
REAR
Preparation:
Set the following controls
Picture.......................... Normal.
Bright ...........................Normal.
Volume ......................... Min. (0).
Procedure:
1. Apply a monoscope pattern.
2. Connect the (-) Lead of the Digital Voltmeter to TP
GND1 (Cold Ground).
3. Connect the (+) Lead of the Digital Voltmeter to
each Test Point and confirm the B+ Voltages (See
Table 3).
PTV Screen Assemblies
Protective Screen
Figure 20. Screen Assemblies.
B+ Voltages Table
Fresnel Screen
(note circular ridges)
No.
Test Point (D-Board)
1
TPD14
2
TPD13
3
TPD12
4
TPD11
5
TPD10
6
C845 (-)
No.
Test Point (A-Board)
1
TPA031
2
TPA030
Table 3: B+ Voltages Table
- 15 -
FRONT
Front Cabinet
Lenticular Screen
(note vertical ridges)
Voltage
138.6
1.0
±
19.0
±
1.5
19.0
1.5
±
-19.0
1.5
±
22.0
1.5
±
-22.5
±
1.5
Voltage
9.0
0.5
±
5.0
0.5
±
Service Manual