General Safety Information; Description - SPX Hankison Trip-L-Trap 505 Instruction Manual

Automatic condensate drains
Table of Contents

Advertisement

I. GENERAL SAFETY INFORMATION
CAUTION
A. Pressurized devices
This equipment is a pressure containing device.
• Do not exceed maximum operating pressure as shown on
equipment serial number tag.
• Make sure equipment is depressurized before working on or
disassembling it for servicing.
B. During each operation of the drain a small amount of system
gas is discharged to atmosphere through the bleed hole in the
piston cylinder.
• Where hazardous or explosive gases are present in the
system, provisions for safe disposal of the discharge must be
provided.
II. DESCRIPTION
These drains are a pilot actuated, pneumatically operated, automatic
liquid drain device for use in discharging collected liquids from a
compressed air system. It is recommended for use with air receivers,
drip legs, aftercoolers, separators, dryers, and filters.
Typical compressed air system
COMPRESSOR
SEPARATOR
AFTERCOOLER
RECEIVER
DRYER
FILTER