One door. Control of the passage of two directions. The relay is in Wet Contact mode............8 Two doors. Control of the passage of one direction. Relay in Wet Contact Mode ..............8 System installation recommendations ............................8 ICON Embedded Website ................................11 ICON / ICON PE 0.12...
2. Network - work in a local network. To work with the controllers, the phone with the "MACS Lite" application must be registered in the same network. 3. Cloudy - work in a local network with cloud connection support. This mode allows you to use all ICON features with minimal effort. The main advantages of this mode: •...
If ICON galvanic isolation from the controlled device (lock, barrier) is required, control of high-voltage devices or devices with significant current consumption (exceeding the rated current for the output), it is recommended to connect these devices via a relay (see Figure 12). It also improves the reliability of the system. When using electromagnetic or electromechanical locks, we strongly recommend using a protective diode (see Figure 11).
- No load output, no more 0,11А Maximum current consumption (at voltage 12V): - No load output, no more 0,3А Maximum switching current: - Output 1 24в 5А - Output 2 12в 3А Maximum switching load voltage of outputs: 24В ICON / ICON PE 0.12...
Page 6
* Maximum identification time, with the number of keys 10,000 - no more than 1.5 s. The controller can work with a large number of user keys, which will lead to an increase in the identification time. ** ICON PE Model ICON / ICON PE 0.12...
Figure 3. One door. The relay is in the "Dry contact" mode. Using a second power supply for the lock Figure 4. Relay in "Dry contact" mode. Figure 5. Separate power supply for the lock. ICON / ICON PE 0.12...
When drawing up a wiring diagram of an object and using Wi-Fi, the controllers should be located as close as possible to the points of the Wi-Fi signal in order to minimize delays in working with a mobile application or cloud service. After ICON / ICON PE 0.12...
Page 9
The maximum permissible load on the built-in POE module in the ICON PE model is no more than 1.5A 12V. Your POE equipment should be capable of delivering 30W of power.
Page 10
The diode must be installed directly on the contacts of the lock. Suitable diodes 1N5400, 1N5408, 1N5821, HER301 and similar. Instead of diodes, varistors can be used, for which there is no need to observe polarity. Varistors VCR-07D101K S07K60, TVR07101, GNR-07D101K or similar are suitable. ICON / ICON PE 0.12...
ICON Embedded Website Initial configuration of ICON is done through the built-in site. To connect to the site, the User must connect to the device's Wi-Fi access point, which has the “ICON” prefix and does not have a password. After connecting to the device, the User must enter the factory IP address of the controller - 192.168.4.1 in the browser line.
Page 12
IP addressing type. In the case of setting the mode "Work through the cloud", we recommend setting in DHCP Device network settings. The device requires 3 ports to work. The default values for these ports are shown. HTTP: 80 DATA port 1: 2777 DATA port 2: 2778 ICON / ICON PE 0.12...
Page 13
- OSDP Port works in OSDP protocol - Own Lumiring equipment operation protocol. Speed - setting the speed of work. Recommended value is 9600. Address - The address of the device in the 485 network. ICON / ICON PE 0.12...
Page 14
Sensor Distance - The user can set the range of the sensor. The selection of the parameter is performed by testing. Figure 16. Device maintenance On this page, the user can update the software and reset the device partially or completely. ICON / ICON PE 0.12...
Page 15
On the "Change platform" tab it is possible to change the platform of the device. The device has two platforms MACS lite and UNIMACS Figure 18. Security Change of username and password of the device. ICON / ICON PE 0.12...