Clearance Dimensions - Fisher & Paykel CG451 Installation Instructions Manual

Hide thumbs Also See for CG451:

Advertisement

CLEARANCE DIMENSIONS

5
A
A
Clearance dimensions
(mm)
A
minimum clearance from left edge of cutout to nearest combustible surface
B
minimum clearance from right edge of cutout to nearest combustible surface
minimum clearance from rear edge of cutout to:
C
nearest combustible surface
nearest non-combustible surface
D
minimum height of non-combustible material when used on adjacent walls
minimum clearance from glass surface to:
rangehood
E
any other overhead exhaust fan
downward facing combustible surface
downwards-facing tiled or fire resistant surface
minimum clearance below top of benchtop to:
F
combustible surface
Fisher & Paykel oven or nearest non-combustible surface
minimum distance from right edge of cooktop to gas connection point on wall
G
(if using a flexible hose)
H
maximum overall depth of overhead cabinetry
Note: Ensure there is an earthed power outlet within reach of the product. The gas connector on the wall should be at least 250 mm (G) outside the width of the product,
on the right-hand side. It should be accessible with the product installed.
H
H
C
C
B
B
ISO
E
E
D
F
F
G
G
FRONT
60
115
60
115
85
125
45
150
150
650
650
800
800
650
650
500
500
70
65
250
250
600
600
D
115
115
125
10
10
150
650
800
650
500
70
70
65
65
250
600
7