5. Not Draining
W/M does not drain.
Start the pump program.
Does pump motor run? This can be
checked by touching the pump filter
with hand. You can sense the noise
of pump motor.
No
Check the continuity between
KN6.3 & pump terminal (blue-
white cable) and KN6.4 & pump
terminal (orange-white cable).
Is it Ok?
No
First check the pump
connection and fix it, but if
there is no problem at the
connections. Change the
main PCB.
Check and clean the pump filter
Drain hose level should be between
Yes
Check the drain hose, it should not
Yes
Change the pump.
16
0.5 and 1 meter from the floor
be bend or broken