Connecting The Remote Control

Fig.10
Only for potential free remote control connections
At the backside of the sunbed, the connector for the remote control is located. The connections
resemble the figure above.
Note: The only purpose of this connection is for controlling the sunbed by means of a coinbox or a
remote control with a potential free switch or contact.
The counterproductive plug can be connected to your control box, timer or coin box.
An incorrect connection of the connector can lead to damage to the parts of the sunbed.
In case you would like to make use of a potential free switch or contact, the parameter P021 of the
SolarControl timer needs to be changed to P021:01 or P021:02 depending upon the application. For
this, please read the user manual of the particular remote control you want to use. The 220-230V
connection is only intended as an exit for connecting the electronics in a remote control (for example
a Paytronic coin box) with a maximal current consumption of 1,0 ampere.
The exit L* delivers 230V in case the machine is turned on. This connection can be used by
applications like feedback signal or occupied signal. Always note that during assembly the plug is
connected in accordance to the manufacturing method (the smooth and ribbed side must be in
accordance with each other).
In case larger distances must be bridged or in case disturbances in the pipes arise, the possibility
exists to place an Opto-box (Ultrasun article number 3T0480) between the remote control pipes.