Resistance/piston type automatic grease lubricator (16 pages)
Summary of Contents for iSHAN YAE-A1/A1P1
Page 1
。 並確遵指示 Welcome on using an iSHAN centralized lubrication systems. Read this owner's manual before installing, operating or maintaining the product. Failure to follow the instructions and safety precautions in this owner’s manual could result in serious injury, death, or property damage.
Page 11
Index 1 Scope of application ..................12 2 Basic operation ....................12 2-1 Safety information ..................12 2-1.1 Before installing ................. 12 2-1.2 Before lubricant filling ............... 13 2-1.3 Control panel safety information ............13 2-1.4 Faults ....................13 2-2 Parts of lubrication unit ................14 2-3 Installing......................
Page 12
1 Scope of application iSHAN centralized lubrication systems are designed to lubricate ball bearings, flat bearings, flat slideways, circular slideways, linear guides, cams, gears, chains, etc.. iSHAN centralized lubrication systems are suitable for the lubrication of various machines, such as lathes, mills, presses, planner, grinder, etc. It is fit to control different lubricating points at the same time against different machines.
Page 13
!iSHAN centralized lubrication systems must not be used in other purposes other than lubricating machines. 2-1.2 Before lubricant filling You must observe the machinery manufacturer's information on the lubricants to be used in the machinery. !Use only new oil with a permitted range of oil viscosity from 30 to 250cSt. Warning !
Page 14
2-2 Parts of lubrication unit 1.Level switch 10.Housing 2.Vent valve 11.Motor 3.Pressure relief(only for YAC-B2/H2) 12.Pressure gauge 4.Oil inlet filter 13.Elbow adapter 5.Bracket 14.Dump valve (only for YAC-B2/H2) 6.Oil tank cap 15.Pump support 7.Beep alarm 16.Gear pump 8.Cable gland 17.Reservoir 9.Control panel Fig.1 14 - 22...
Page 15
2-3 Installing 2-3.1 Positioning and mounting The lubrication unit is attached to the intended mounting location (3) using appropriate fastening materials (1). The mounting dimensions of fixing holes are measured at 205mm. The installation location should be spaced between 0.6m to 1.7m above the ground.
Page 16
2-3.4 Wiring and alarm Warning !! To prevent chance of serious injury, death or property damage, disconnect the product from main power supply before working on it. Install a fuse between the power supply and the product is strongly recommended! The electrical circuit diagram of the lubrication unit is affixed inside the unit and can be accessed by removing the cap.
Page 17
YAE-A1/A1P1 is equipped with pressure regulator (Fig. 10) to adjust built-in pressure. First loose the nut (2) and turn on the power. After the lubricant comes out from the pressure relief valve, screw in the knob (1) until pressure build-in in the centralized lubrication system per the user’s required pressure.
Page 18
Press RES button (Fig. 11) for two seconds, the lubrication unit will restart up and then run default setting to deliver lubricant. 3-5 Operating mode setting Only allow authorized person by iSHAN company to change default setting. The Warning !! user only can adjust time for lubrication or intermittence.
Page 19
Warning! Never use used lubricant 4 Maintenance iSHAN centralized lubrication system is easy to maintain. The reservoir must be cleaned before installation and in service time so clean the reservoir regularly. If there is any impurity or oil sludge found at the bottom of reservoir or on the strainers of the lubrication unit, disconnect the product from main power supply and take off the reservoir by removing 4 screws on the corners.
Page 20
God. Any return must consult with iSHAN and obtain iSHAN’s approval before action. 7 Announcement Warning:iSHAN reserves the right to make content and technical changes without notice and it includes the manual. It is invalid to file a lawsuit against iSHAN in above changes. 20 - 22...
Page 21
8.Technical data 8-1 Specification YAE-A1 YAE-A2 /A1P1 /A2P2 110V 50 / 60 Hz 110V 50 / 60 Hz Power supply 220V 50 / 60 Hz 220V 50 / 60 Hz Consumption power (max.) 25 W (max.) 25W (max.) Max. output volume 300 ml / min 150 ml / min Max.
If you have technical queries, please contact one of the 臺灣總部: following plants. 臺灣省臺中市龍井區台西南路 256 巷 28 弄 5 號 Manufacturer : TEL:+886-4-26302881 ishan Precision Industry Co., Ltd. FAX:+886-4-26302880 Add: No. 5, Alley 28, Lane 256, Tai Si S. Rd, Lung E-mail:ishan@tcts.seed.net.tw Ching Hsiang, TaichungHsien, Taiwan Http://www.ishan.com.tw...