Resistance/piston type automatic grease lubricator (16 pages)
Summary of Contents for iSHAN YET-D1
Page 1
感謝您購買裕祥集中潤滑給油系統,爲了適當使用而無問題,請詳細閱讀本手冊並確 遵指示。 Welcome on using an iSHAN centralized lubrication systems. Read this owner's manual before installing, operating or maintaining the product. Failure to follow the instructions and safety precautions in this owner’s manual could result in serious injury, death, or property damage.
Page 12
Index 1 Scope of application....................13 2 Basic operation......................13 2-1 Safety information.......................13 2-1.1Before installing......................13 2-1.2Before lubricant filling....................14 2-1.3 Control panel safety information................14 2-1.4 Faults........................14 2-2 Parts of lubrication unit....................... 15 2-3 Label instruction........................15 2-4 Installation...........................17 2-4.1 Positioning and mounting..................17 2-4.2 Filling Oil.........................
Page 13
1 Scope of application iSHAN centralized lubrication systems are designed to lubricate ball bearings, flat bearings, flat slideways, circular slideways, linear guides, cams, gears, chains, etc.. iSHAN centralized lubrication systems are suitable for the lubrication of various machines, such as lathes, mills, presses, planner, grinder, etc. It is fit to control different lubricating points at the same time against different machines.
Page 14
!iSHAN centralized lubrication systems must not be used in other purposes other than lubricating machines. 2-1.2 Before lubricant filling You must observe the machinery manufacturer's information on the lubricants to be used in the machinery.
Page 15
2-2 Parts of lubrication unit Cover cap Alarm Cable gland Pressure gauge Display and control panel Straight adapter Oil tank cap Dump valve(for YET-D2) Mounting board Oil inlet filter Coupling Reservoir Pressure relief valve Level switch Gear pump Housing Fig.1 15 - 23...
Page 16
2-3 Label instruction Model label Electric Shock Positioned on the right front side of housing Positioned on the cover of housing Wiring instruction Operation Instruction (YET-D) Positioned inside housing Left side of tank YET-D time setting table (Positioned inside the cover cap) 16 - 23...
Page 17
2-4 Installation 2-4.1 Positioning and mounting The lubrication unit is attached to the intended mounting location (3) using appropriate fastening materials (1).The mounting dimensions of fixing holes for 2L are measured between 172 to 180mm ; 3L between 190 to 205mm ; 4L between 230 to 250mm.
Page 18
2-4.4 Wiring and alarm Install a fuse between the power supply and the product is strongly recommended! The electrical circuit diagram of the lubrication unit is affixed inside the unit and can be accessed by removing the cap. Remove the cap (Fig.5) and inside you can see terminal plate and cable gland nut. Loosen cable gland (Fig.6) and then insert cable through the cable gland hole (Fig.7) to wire up.
Page 19
(Fig.5) (Fig.6) (Fig.7) (Fig.8) 3 General information 3-1 Time setting Lubrication time: orange light on, unit second. Intermittent time: green light on, unit minute. Please turn off the power before time setting. Remove the cover cap, there are two sets of switches on the circuit board, the upper one is for lubrication time, the lower one is for intermittent time.
Page 20
Warning! Never use used oil 4 Maintenance iSHAN centralized lubrication system is easy to maintain. The reservoir must be cleaned before installation and in service time so clean the reservoir regularly. If there is any impurity or oil sludge found at the bottom of reservoir or on the strainers of the lubrication unit, disconnect the product from main power supply and take off the reservoir by removing 4 screws on the corners.
Page 21
Check the electrical connection. results in damage of electrical Check voltage. circuit. Return the lubrication unit with faults to iSHAN or iSHAN distributor/agent for verification and repair. Oil viscosity is too high to Send back the machine to repair. burn the motor Use oil with 30~250cSt viscosity.
Page 22
6 Warranty iSHAN warrants that it will repair or replace any product manufactured and sold by it which proves to be defective in material or workmanship within a period of one year from the date of original purchase for the clients. Any warranty claim will be considered invalid if the product is not complete or it was disassembled or failure to manual or damage caused by act of God.
If you have technical queries, please contact one of the 臺灣總部: following plants. 臺灣省臺中市龍井區台西南路 256 巷 28 弄 5 號 Manufacturer : TEL:+886-4-26302881 ishan Precision Industry Co., Ltd. FAX:+886-4-26302880 Add: No. 5, Alley 28, Lane 256, Tai Si S. Rd, Lung E-mail:ishan@tcts.seed.net.tw Ching Hsiang, TaichungHsien, Taiwan Http://www.ishan.com.tw...