11. Maintenance

These dosing pumps are produced to the highest quality standards, and have a long service life. Nevertheless, some of their parts are subject to wear due to
operation (e.g. diaphragms, valve seats, valve balls). Regular visual inspections are therefore necessary in order to ensure a long operating life. Periodic mainte-
nance will protect the dosing pump from operation interruptions. The manufacturer recommends maintenance once per year, provided the local regulations do not
specify more frequent maintenance.

11.1 Lubrication

®
The Encore
MB/ME diaphragm dosing pump requires little maintenance. The dosing pump gear is lubricated with gear oil of viscosity class ISO-VG460 accord-
ing to DIN 51519 (corresponds to SAE 140 according to DIN 51512). The first filling, which is supplied with the product, is to be replaced after 5,000 operating
hours or 1 year, whichever comes first. Further oil changes should be conducted after 10,000 operating hours or 2 years, whichever comes first. The filling
capacity is about 0.25 l for gears of sizes up to Encore
required can be determined by checking the min./max. marks on the oil dipstick.
ATTENTION!
®
Encore
MB: To avoid damage to the approximation initiator, the dosing pump must be switched off before taking out the oil dipstick.

11.2 Maintenance of the bearings

The upper bearing of the pinion shaft is a sealed and permanently lubricated ball bearing. In the Size I Encore
performed by the drive side motor bearing. The other roller bearings in the gearing, and the plain bearings of the diaphragm rod, are lubricated by the gear oil.
The oil also performs a heat dissipation function.
All bearings must be examined for wear after 10000 hours of operation. The service life of the roller bearings depends on the applied loads.

11.3 Maintenance of the ATE servomotor (optional)

The ATE servomotor is given permanent lubrication at the factory. Nevertheless, regular inspections are recommended if the drive is operated in tough operating
conditions, for example in high ambient temperatures or continuous operation.

11.4 Diaphragm replacement

CAUTION!
Chemical may spray out. This may lead to chemical or other burns. The dosing pump must always be depressurized and rinsed with water or a suitable medium
before starting any work on the dosing pump.
b
a
32
MB/ME
®
MB/ME 156 and about 0.7 l for gears of sizes up to Encore
f
e
d
c
a Dosing head with discharge and suction valve
b Diaphragm
c Support plate (only ME/MB 50,75,76)
d Diaphragm rod
e Diaphragm flange
f Gear housing