Accuracy (cont'd)
Resistance and Conductance (Conductance on DM-820A, DM-830A, and DML-430A Only)
Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
99.99 nS
Continuity
Tone Threshold: Between 20 Ω and 300 Ω
Response Time: < 100 µs
Capacitance
Range
60.00 nF
600.0 nF
6.000 µF
60.00 µF
600.0 µF
6.000 mF
25.00 mF
(1)
Accuracies with film capacitor or better
(2)
In manual ranging mode, measurements are not specified below 50.0 µF, 0.54 mF, and 5.4 mF for
600.0 µF, 6.000 mF and 25.00 mF ranges, respectively
Diode Test
Measuring Range: 2.000 V
Test Current (typical): 0.4 mA
Open Circuit Voltage: < 3.5 VDC
Accuracy: 1.0% + 0.001 V
± (0.1% + 0.3 Ω)
± (0.1% + 0.003 kΩ)
± (0.1% + 0.03 kΩ)
± (0.1% + 0.3 kΩ)
± (0.4% + 0.003 MΩ)
± (1.5% + 0.05 MΩ)
± (0.8% + 0.1 nS)
± (0.8% + 0.03 nF)
± (0.8% + 0.3 nF)
± (1.0% + 0.003 µF)
± (2.0% + 0.03 µF)
(2)
± (3.5% + 0.5 µF)
(2)
± (5.0% + 0.005 mF)
(2)
± (6.5% + 0.05 mF)
DM-810A • DM-820A • DM-830A • DML-430A
Accuracy
Accuracy
(1)
Typical Open Circuit Voltage
1.2 VDC
1.2 VDC