Hussmann RI1 Technical Data Sheet
Hussmann RI1 Technical Data Sheet

Hussmann RI1 Technical Data Sheet

Hussmann ri1 merchandisers: data sheet
Hide thumbs Also See for RI1:

Advertisement

B
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
,
8 Ft, 10 Ft, 12 Ft
14 Ft & 16 Ft
A. 12W Standard Fan Assembly
0047000
Fan Motor, Evaporator
(MO.4410103)
0407532
Fan Blade (FB.4780619)
embossing toward motor
12W Energy Efficient Fan Assembly
0477655
Fan Motor, Evaporator
(MO.4410546)
0407532
Fan Blade (FB.4780619)
B. Optional Adjustable Refrigeration Thermostat (2)
0448347
(CT.4481631)
Note: Revision B corrects the part numbers and Aftermarket part numbers.
©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
A
D
Wiring Item #
®
E
Item Part #
H
EATERS
C.
0447688
(1)
L
B
AMPS AND
ALLASTS
D. Ballast, Electronic
0447683
(1)
E.
Technical Data Sheet
P/N 0492428_B
NSF
®
Certified
April 2007
C
Description
Wiring Item #
Anti-Sweat Heater
(HE.4850682)
(BA.4440811)
Fluorescent Lamp
Replace with like fixtures
P/N 0492428_B
RI1
(3)
(4)
(5)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RI1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hussmann RI1

  • Page 1 B. Optional Adjustable Refrigeration Thermostat (2) 0448347 (CT.4481631) Note: Revision B corrects the part numbers and Aftermarket part numbers. ©2006 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM ® Wiring Item # Item Part # EATERS...
  • Page 2: Plan Views

    Schedule 40 PVC drip pipe Refrigeration Outlet LH end of case to center of refrigeration outlet RH end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Refrigeration & Coil Stubout Drains Front...
  • Page 3: Refrigeration Data

    Air flow between the shelves, from the CAD to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated. P/N 0492428_B HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM (102) (260) (152)
  • Page 4: Electrical Data

    115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 8 ft 10 ft 12 ft...
  • Page 5 All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White = 120V P OWER P/N 0492428_B HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Anti-sweat Heaters WARNING IRCLED NUMBERS ARTS...
  • Page 6 G = Green BL = Blue B = Black W = White = 120V P = 120V N = Field G = Case G OWER EUTRAL ROUND ROUND 6 of 6 RI1 Technical Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

Table of Contents