Hussmann RI2N Technical Data Sheet
Hussmann RI2N Technical Data Sheet

Hussmann RI2N Technical Data Sheet

Multi-deck island
Hide thumbs Also See for RI2N:

Advertisement

B
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
,
8 Ft, 10 Ft, 12 Ft
14 Ft & 16 Ft
A. 12W Standard Fan Assembly
0047000
Fan Motor, Evaporator
(MO.4410103)
0142780
Fan Blade (FB.0142780)
embossing toward motor
12W Energy Efficient Fan Assembly
0477655
Fan Motor, Evaporator
(MO.4410546)
0142780
Fan Blade (FB.0142780)
B. Optional Adjustable Refrigeration Thermostat (2)
0448347
(CT.4481631)
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
®
A
Wiring Item #
(1)
(1)
E
Item Part #
Description
H
EATERS
C.
Anti-Sweat Heater
0487118
(HE.4850668)
L
B
AMPS AND
ALLASTS
D. Ballast, Electronic
0355398
(BA.4480118)
0355716
(BA.0355716)
0447740
(BA.4481278)
E.
Fluorescent Lamp
Replace with like fixtures
RI2N
Technical Data Sheet
P/N 0492430_A
NSF
®
Certified
January 2007
C
E
Serial Plate
Wiring Item #
P/N 0492430_A
(3)
(4)
(5)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RI2N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hussmann RI2N

  • Page 1 0142780 Fan Blade (FB.0142780) B. Optional Adjustable Refrigeration Thermostat (2) 0448347 (CT.4481631) ©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM ® Wiring Item # Item Part # EATERS 0487118 AMPS AND ALLASTS D.
  • Page 2 Schedule 40 PVC drip pipe Refrigeration Outlet LH end of case to center of refrigeration outlet RH end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Refrigeration & Coil Stubout Drains Front...
  • Page 3: Load Limit Profile

    Air flow between the shelves, from the CAD to the return, must be maintained at all times for optimum operating efficiency and to prolong product shelf life. At no time should merchandisers be stocked beyond the load limits indicated. P/N 0492430_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 1 /8 (203) (305)
  • Page 4: Electrical Data

    115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 8 ft 10 ft 12 ft...
  • Page 5 All components must have mechanical ground, and the merchandiser must be grounded. R = Red Y = Yellow G = Green BL = Blue B = Black W = White = 120V P OWER P/N 0492430_A HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Anti-sweat Heaters WARNING IRCLED NUMBERS ARTS...
  • Page 6 R = Red = 120V P = 120V N OWER 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RANGE OR WARNING Circled Numbers = Parts List Item Numbers G = Green BL = Blue B = Black W = White...

Table of Contents