Replacing the upper stamp
Press the eyelet channel to the side to allow easier handling.
Figure G
15
Malfunctions in the eyelet feed
The eyelet feed is set up for a single eyelet size. If eyelets of a different size,
defective eyelets, dirt or other foreign objects get into the eyelet container or the
feed, malfunctions will occur.
Remove the tension spring that holds the eyelet channel to the body.
Remove the eyelet container (see "Replacing the bristle disk"). (Figures H–K)
First empty the eyelet container, or the eyelets will scatter everywhere.
Repair the cause of the malfunction.
Reinstall the eyelet container.
BA_09/2018en
Screw out the upper stamp [18] using the (size 12)
open-ended spanner provided.
If the catch pin [19] also has to be replaced, user
pliers to pull it down and out. Figure G.
Insert the new catch pin through the new upper
stamp and turn both of them together into the tappet.
Do an eyeleting test and, if necessary, readjust the
pressure. (See "Adjusting the pressure").