User Manual - Typhoon Open –
B. Option Two timers – Petrol & Diesel series:
The system consists of two timer controlled condensate drains, one after the 2
the BA filter. The drains are controlled electronically and open automatically.
In case of emergency (damaged auto drain system), the user may use the two manual drains. During routine
operation open both drain valves every 20 minutes.
C. Option One timer – New Versions:
The system consists of one timer, located inside compressor's electrical box. It controls electornically both 2
stage condensate drains, which open automatically.
In case of emergency (damaged auto drain system), the user may use the two manual drains. During routine
operation open both drain valves every 20 minutes.
Pause Time = 20 min
Signal Time = 2 – 3 seconds – set signal time first
Important Note: Do not change manufacturer adjustments.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
01/2018 edition
nd
2
1
The user can adjust the interval time (2) from 0,5 -
45 min (proposed time 20min), and the discharge
time (1) from 0,5 - 10 sec (proposed time 2 sec).
service@paramina.gr
nd
rd
& 3
Stage
2
- website:
www.paramina-compressors.com
, and one after the final stage and
nd
rd
& 3
.
17