General Service Instructions - Paramina Typhoon Open 13E User Manual

Table of Contents

Advertisement

User Manual - Typhoon Open –
General Service Instructions 
o
CAUTION: Before any maintenance on the compressor, make sure there is not air inside, under pressure.
Every time you stop the compressor, ALWAYS
o
Maintenance must always be done with the compressor stopped and disconnected from the mains
supply.
Every
20 hrs
Check
V - Belt tension
1
Check oil level
&
Condensate drain system
2
Change of oil
Replace air intake cartridge
3
Replace BA
Open 13
cartridge –
Filter Ø80 x
2
535
Open 15
Replace BA
Open 15
cartridge –
Filter Ø110 x
2
495
Open 18
Replace coalescing
3
cartridge
Check Valves
Replace Valves
Replace pistons
and piston rings
Sintered Filter (Interstage
& Final stage Separator –
6
drawing at page 63)
5
Service Kit 1000hrs
(p.n.190961500
or190961510)
5
Service Kit 2000hrs
(p.n.190961600 or
190961610)
Replace filling hoses
ATTENTION
1. Check every day the oil level and the general condition of the compressor. Check all connections for leakage.
2. After 6 months, you have to replace the oil and the BA filter's cartridge(s), whether they have completed the required
operating hours or not. If the compressor is out of operation for a long period of time, you must also replace them before
restart.
The proper quantity of oil, when you replace it, is 2,2 lit.
Never mix different types of oil.
The compressor unit is delivered filled with PARAMINA HPS OIL (Synthetic oil) with p.n.112001000.
3. After 12 months, you have to replace the coalescing cartridge and the air intake cartridge whether they have completed the
required operating hours or not.
o
4. Measured @ 20
C ambient temperature.
5. Service Kits, o-rings & Teflon may need to be replaced at undefined periods according to several factors.
6. Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 & 208704200.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email:
01/2018 edition
Every 30
Every
Every 100
hrs
50 hrs
st
1
st
1
4
25 hrs
4
X
4
35 hrs
4
28 hrs
service@paramina.gr
open the manual drains so as to remove condensate.
Operating hours
Every
Every
hrs
200 hrs
500 hrs
X
Daily
X
X
X
X
X
clean
- website:
www.paramina-compressors.com
Every 1000
Every 2000
Every 6
hrs
hrs
mths
X
X
X
replace
X
X
X
Every
12 mths
X
X
X
X
X
X
X
Once per
5 years
.
39