Paramina Typhoon Open 13E User Manual page 18

Table of Contents

Advertisement

User Manual - Typhoon Open –
01/2018 edition
Note 1: Condensate color is milky-white. If condensates suddenly change color or start smelling, this is indication of
oil presence. Immediately check:
1. oil quality
2. oil level
3. filters' condition and especially the condition of active carbon filter
4. air inlet filter's condition
5. piston rings and cylinders condition
5
Note 2: All petrol compressors are equipped with an auto drain switch (5). Turn on this switch always before
engine start and turn it off after finalizing all works (otherwise compressor's battery will be empty).
EMERGENCY START TOGGLE SWITCH
IMPORTANT NOTE: DO NOT USE THIS SWITCH UNLESS YOU HAVE FULLY UNDERSTOOD HOW IT WORKS.
USE THIS SWITCH ONLY IF BATTERY IS TOTALLY DRAINED OUT
Attention: This switch deactivates all the operating – safety functions and detours all functions (pressure switch –
low compressor oil alarm), allowing manual engine start.
How to use the emergency toggle switch:
If the battery has drained out and is not possible to start the engine via the electric starter, turn the switch to
MANUAL position (run without battery) and start the engine manually. After engine starts, RETURN the switch to
the RUN position (run with battery).
Attention: Before using this switch, ensure that there is no other reason that prevents the unit from starting
electrically (low oil level in engine or on compressor, high pressure on final stage, engine protection activated,
lack of fuel, or any other reason)
DO NOT RUN THE COMPRESSOR WITH BATTERY DISCONNECTED
.
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
18
Fax: 0030 210 5575868, email:
service@paramina.gr
- website:
www.paramina-compressors.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents