INFORMATION
Some of the functions CANNOT be used in the test run
operation mode.
If a power failure occurs during operation, the system automatically
restarts immediately after power is restored.
12

Disposal

NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
13

Technical data

▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
13.1

Wiring diagram

The wiring diagram is delivered with the unit, located on the
inner right side of the indoor unit front grille.
13.1.1

Unified wiring diagram legend

For applied parts and numbering, refer to the wiring diagram on the
unit. Part numbering is by Arabic numbers in ascending order for
each part and is represented in the overview below by "*" in the part
code.
Symbol Meaning
Symbol Meaning
Circuit breaker
Connection
,
Connector
Earth
Field wiring
Fuse
Indoor unit
INDOOR
Outdoor unit
OUTDOOR
Residual current
device
Symbol
Colour
Symbol
BLK
Black
ORG
BLU
Blue
PNK
BRN
Brown
PRP, PPL
GRN
Green
RED
GRY
Grey
WHT
SKY BLU Sky blue
YLW
FTXP-N
Daikin room air conditioner
3P695637-2A – 2022.06
Protective earth
Protective earth (screw)
A
Rectifier
,
Relay connector
Short-circuit connector
Terminal
Terminal strip
Wire clamp
Colour
Orange
Pink
Purple
Red
White
Yellow
Symbol
A*P
BS*
BZ, H*O
C*
AC*, CN*, E*, HA*, HE*, HL*,
HN*, HR*, MR*_A, MR*_B, S*, U,
V, W, X*A, K*R_*, NE
D*, V*D
DB*
DS*
E*H
FU*, F*U, (for characteristics,
refer to PCB inside your unit)
FG*
H*
H*P, LED*, V*L
HAP
HIGH VOLTAGE
IES
IPM*
K*R, KCR, KFR, KHuR, K*M
L
L*
L*R
M*
M*C
M*F
M*P
M*S
MR*, MRCW*, MRM*, MRN*
N
n=*, N=*
PAM
PCB*
PM*
PS
PTC*
Q*
Q*C
Q*DI, KLM
Q*L
Q*M
Q*R
R*
R*T
RC
S*C
S*L
S*NG
S*NPH
S*NPL
S*PH, HPS*
12 Disposal
Meaning
Printed circuit board
Pushbutton ON/OFF, operation
switch
Buzzer
Capacitor
Connection, connector
Diode
Diode bridge
DIP switch
Heater
Fuse
Connector (frame ground)
Harness
Pilot lamp, light emitting diode
Light emitting diode (service
monitor green)
High voltage
Intelligent eye sensor
Intelligent power module
Magnetic relay
Live
Coil
Reactor
Stepper motor
Compressor motor
Fan motor
Drain pump motor
Swing motor
Magnetic relay
Neutral
Number of passes through ferrite
core
Pulse-amplitude modulation
Printed circuit board
Power module
Switching power supply
PTC thermistor
Insulated gate bipolar transistor
(IGBT)
Circuit breaker
Earth leak circuit breaker
Overload protector
Thermo switch
Residual current device
Resistor
Thermistor
Receiver
Limit switch
Float switch
Refrigerant leak detector
Pressure sensor (high)
Pressure sensor (low)
Pressure switch (high)
Installation manual