Elitech STC-1000Pro TH Quick Start Manual

Elitech STC-1000Pro TH Quick Start Manual

Intelligent temperature and humidity controller

Advertisement

STC-1000Pro TH / STC-1000WiFi TH
Intelligent Temperature and Humidity Controller
Tsv
Hsv

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STC-1000Pro TH and is the answer not in the manual?

Questions and answers

Summary of Contents for Elitech STC-1000Pro TH

  • Page 1 STC-1000Pro TH / STC-1000WiFi TH Intelligent Temperature and Humidity Controller...
  • Page 2 1. Introduction STC-1000Pro TH / STC-1000WiFi TH is an integrated plug-and-play temperature and humidity controller. It has temperature and humidity integrated probe and is pre-connected to two output sockets to control temperature and humidity simultaneously. The large LCD screen intuitively displays temperature, humidity, and other parameters.
  • Page 3: Display Introduction

    2.1 Display Introduction Please check the instructions below before parameter configuration. 1 2 3 4 5 6 7 Fig. 2 Status Icon Function Flashing Resetting Wi-Fi connection status connected Protection delay Cooling status Alarm status No alarm Alarm Heating Status Protection delay Humidification status Protection delay...
  • Page 4: Parameter Table

    2.2 Parameter Table 9 10 11 12 13 14 15 16 Fig. 3 Code Function Setting range Default value Temperature cooling/heating C / H mode selection -5 ~ 70°C Temperature set value 23 -158°F 0.2 ~ 15°C Temperature di erential 1 ~ 30°F Temperature 0 ~ 10 Min...
  • Page 5 Code Function Setting range Default value Dehumidifying/ Humidifying H / D mode selection Humidity set value 5 ~ 99%RH Humidity 1 ~ 30%RH di erential Humidity 0 ~ 10 Min protection time Humidity alarm 5 - 99%RH high limit Humidity alarm 5 - 99%RH low limit Humidity...
  • Page 6: Button Operation

    2.3 Button Operation Setting mode Non-setting Operating S/N Button Number Number Remarks mode flashing non-flashing Previous View parameter Press Increases parameter value Press and Continuous hold increases Number Number Press non-flashing flashing Press and hold for 3 Setting mode Non-setting mode seconds View parameter Next...
  • Page 7: Sensor Installation

    3.1 Sensor Installation Plug the probe fully to the bottom of the main controller's headphone jack. Otherwise, a buzzer alarm will be triggered, and the "Err" code will show on the LCD after powering the controller. Fully Plug In Fig. 4 3.2 Power-on Please insert the power plug into the power socket to power on the control- ler (within the range of 100-240VAC).
  • Page 8: Parameter Setting

    3.3 Parameter Setting Press and hold button for 3 seconds to enter the parameter setting mode, the buzzer will beep, and the LCD will display icon. In the menu setting, press button and the Tsv parameter light will be on or flashes.
  • Page 9 Fig. 6 Fig. 7...
  • Page 10: Function Description

    4. Function Description 4.1 Temperature Setting - TCH, TS, TD Cooling mode (TCH = C) When T (temperature-present value) is higher than TS + TD (temperature-set value + temperature di erential), will appear, work1 will be turned on, and cooling will begin; WORK1 On When T (temperature-present...
  • Page 11 4.3 Temperature Alarm Limit- TAH, TAL When T (temperature-present value) is higher than TAH (temperature alarm high limit), the temperature alarm high limit will be triggered and code will be displayed; When T (temperature-present value) is lower than TAL (temperature alarm low limit), the temperature alarm low limit will be triggered and code will be displayed;...
  • Page 12 Humidifying Mode (TCH = H) When H (humidity-present value) is lower than HS-HD (humidity set value - humidity di erential), will appear, work2 will be turned on, and WORK2 On Humidifying will begin; WORK2 O When H (humidity-present value) is higher than HS (humidity set value), HS=50 HD=10...
  • Page 13: Equipment Installation

    4.10 Continuous Operating Time - COT During humidity control, when COT≠0 and output conditions are met, WORK2 socket will work in on-o -on-o ..mode. COT is time on as well as time o . eg, if COT=10, the WORK2 output socket will turn on for 10 minutes and o for 10 minutes, then repeat.
  • Page 14: Restore Factory Settings

    6. Alarm In the following circumstances during operation, the buzzer will give a "bi-bi-Biii" alarm, and at the same time, the alarm symbol on the screen will appear. Press any button to mute the alarm. Code Function Socket output status Sensor failure Outputs terminated Temperature alarm high limit...
  • Page 15 STC-1000WIFI TH has embedded the Wi-Fi module that supports remote viewing, configuartion and other operations via Elitech app. ● Download the latest “Elitech iCold” app from APP Store or Google Play, register you free Elitech account and singn in. ● Connect your mobile phone to preferred Wi-Fi (2.4GHz Wi-Fi, 5GWi-Fi is not compatible).
  • Page 16 6.A window will pop up "The device scanned is a Wi-Fi device. Would you like to set Wi-Fi?"Click OK. (GMT+00:00) Europe/London Fig. 16 7. Enter Wi-Fi password, click OK, and wait until the operation finishes. The whole process takes about 10 seconds.
  • Page 17: Technical Parameters

    9. Technical Parameters Working voltage: 100~240VAC, 50/60Hz Temperature measurement range: -5~70°C / 23~158°F Temperature control range: -5~70°C / 23~158°F Temperature measurement accuracy: ±0.5°C /±1°F Temperature resolution: 0.1°C /0.1°F Humidity measurement range: 5~99%RH Humidity control range: 5~99%RH Humidity measurement accuracy: ±5%RH Humidity resolution: 0.1%RH Relay contact output capacity: 10A (resistive) / 100 ~ 240VAC Output power: 2200W (resistive) in total/...
  • Page 18 MADE IN CHINA V1.1...